首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Chemiluminescence immunoassay of thyrotropin with acridinium-ester-labeled antibody evaluated and compared with two other immunoassays.
【24h】

Chemiluminescence immunoassay of thyrotropin with acridinium-ester-labeled antibody evaluated and compared with two other immunoassays.

机译:评估了促甲状腺素与a啶酯标记的抗体的化学发光免疫分析,并将其与其他两种免疫分析进行了比较。

获取原文
           

摘要

A new chemiluminometric immunoassay of thyrotropin (TSH) involves antibody labeled with acridinium ester ("Magic Lite System," Ciba Corning Diagnostic Corp.). The assay is rapid, with two incubations totaling 2.5 h, requires two standards per run, and takes 10 s per sample for the quantification step. Analytical performance, within- and between-run reproducibilities, and linearity were excellent. The detection limit is 0.04 milli-int. unit/L. Results correlated well with those obtained by immunoradiometric assay (RIA-gnost hTSH, Hoechst-Behring) and immunofluorometric assay (hTSH Delfia, LKB): r = 0.975. TSH measurements in 32 euthyroid subjects ranged from 0.4 to 4.8 milli-int. units/L (mean 1.35 milli-int. units/L). TSH values for 51 hypothyroid and subclinically hypothyroid patients ranged from 2 to 65 milli-int. units/L. TSH values for 33 hyperthyroid patients (less than 0.14 milli-int. unit/L, less than 0.04 milli-int. unit/L in 16 of the 33) were clearly lower than for most untreated euthyroid subjects. For 169 other individuals whose thyroid function was being routinely assessed. TSH ranged from 0.4 to 4.8 milli-int. units/L, three had TSH less than 0.14 milli-int. unit/L, and four had TSH between 0.14 and 0.4 milli-int. unit/L. This system is as efficient and reliable for screening for thyroid function as the two comparison systems.
机译:促甲状腺素(TSH)的化学发光免疫测定涉及一种用with啶酯标记的抗体(“ Magic Lite System”,Ciba Corning Diagnostic Corp.)。该测定快速,两次孵育共2.5小时,每次运行需要两种标准品,每个样品需要10 s进行定量步骤。分析性能,批内和批间重复性以及线性均非常好。检出限为0.04毫INT。单位/升结果与通过免疫放射测定(RIA-gnost hTSH,Hoechst-Behring)和免疫荧光测定(hTSH Delfia,LKB)获得的结果密切相关:r = 0.975。在32名甲状腺功能正常的受试者中,TSH的测量值范围为0.4至4.8毫INT。单位/升(平均1.35毫国际单位/升)。 51名甲状腺功能减退和亚临床甲状腺功能减退患者的TSH值范围为2到65毫int。单位/升33例甲状腺功能亢进患者的TSH值(33例中的16例小于0.14毫国际单位/ L,小于0.04毫国际单位/ L)明显低于大多数未经治疗的甲状腺正常受试者。对于另外169名常规评估甲状腺功能的个体。 TSH的范围为0.4到4.8毫整数。单位/升,其中三个的TSH小于0.14毫升。单位/升,其中四个的TSH在0.14到0.4毫整数之间。单位/升该系统与两个比较系统一样,高效,可靠地筛查甲状腺功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号