We describe a sensitive, accurate automated method for the simultaneous measurement of methemoglobin and total hemoglobin in blood. The method can be used for either continuous in vivo monitoring or intermittent sampling at a rate of 20/h. Standardization procedures are described, in which human blood treated with sodium nitrite is used. Repeatability of methemoglobin and total hemoglobin measurements, expressed as coefficient of variation in percent, are within ±4.1 and ±2.6%, respectively. Normal methemoglobin concentration’s in humans and dogs did not exceed 0.55 g/dl (3.3% of the total hemoglobin).
机译:我们描述了同时测量血液中高铁血红蛋白和总血红蛋白的灵敏,准确的自动化方法。该方法可用于连续体内监测或以20 / h的速率进行间歇采样。描述了标准化程序,其中使用了经过亚硝酸钠处理的人血。高铁血红蛋白和总血红蛋白测量值的重复性以百分比变异系数表示,分别在±4.1%和±2.6%之内。人和狗的正常高铁血红蛋白浓度不超过0.55 g / dl(占总血红蛋白的3.3%)。