Radioimmunoassay for urinary lysozyme in human serum from leukemic patients.

机译:白血病患者人血清中尿溶菌酶的放射免疫分析。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

We present a radioimmunoassay for lysozyme in human serum, based upon human lysozyme isolated from the urine of leukemic patients and antiserum prepared against this lysozyme in the goat. In the separation step, a second antibody is used. By properly adjusting the concentrations of unlabeled and 125I-labeled lysozyme and of the antibodies, maximal precision (SD, 0.04 mg/litre) was obtained in the range 0.00 to 2.00 mg/litre. In 20 normal volunteers the lysozyme concentration was 4.6 +/- 0.8 mg/litre (mean +/- SD), in 13 patients with monocytic leukemia 34.4 +/- 8.6 mg/litre. Correlation with lysoplate determinations was excellent in leukemic sera (r = 0.97) but was poor in normal sera (r = 0.35), possibly owing to the existence of isoenzymes.
机译:我们基于从白血病患者尿液中分离出的人溶菌酶和针对山羊的这种溶菌酶制备的抗血清,对人血清中的溶菌酶进行了放射免疫分析。在分离步骤中,使用第二抗体。通过适当调节未标记和125I标记的溶菌酶和抗体的浓度,可以在0.00至2.00 mg / L的范围内获得最大的精密度(SD,0.04 mg / L)。在20名正常志愿者中,溶血酶浓度为4.6 +/- 0.8 mg / L(平均+/- SD),在13例单核细胞白血病患者中,溶菌酶浓度为34.4 +/- 8.6 mg / L。与溶血板测定的相关性在白血病血清中极佳(r = 0.97),而在正常血清中则较差(r = 0.35),这可能是由于同工酶的存在。