首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Ultramicro Method for Determination of Iron in Serum with the Graphite Furnace
【24h】

Ultramicro Method for Determination of Iron in Serum with the Graphite Furnace

机译:石墨炉超微法测定血清铁。

获取原文
           

摘要

An ultramicro method is described for determining iron in 50 μl of serum. Hot trichloroacetic acid is used to remove protein and hemoglobin iron, and atomic absorption analysis of 10 μl of the supernatant fluid is carried out with use of a graphite furnace and a specially grooved graphite tube. Results correlate well with those obtained by a conventional flame atomic absorption method for iron that requires a 1-ml sample of serum. A standard graphite tube can be used if the trichloroacetic acid extract is first diluted with water, but we rejected this procedure because of the extra time and effort involved and because of the increased problem of artifactual contamination with iron. When serum was analyzed with no pretreatment, results were higher, probably because of hemoglobin iron present in serum, even serum with no visible hemolysis.
机译:描述了一种超微方法,用于测定50μl血清中的铁。使用热三氯乙酸去除蛋白质和血红蛋白铁,并使用石墨炉和特殊开槽的石墨管对10μl上清液进行原子吸收分析。结果与通过常规火焰原子吸收法获得的铁(需要1毫升血清样品)具有很好的相关性。如果首先用水稀释三氯乙酸萃取液,则可以使用标准石墨管,但由于涉及额外的时间和精力,并且由于人为污染铁的问题增加,我们拒绝此程序。在不进行预处理的情况下分析血清时,结果较高,这可能是因为血清中存在血红蛋白铁,甚至是没有明显溶血的血清。