Objective To evaluate the reference values for short-term heart rate variability (HRV), estimate the performance of cardiovascular autonomic neuropathy (CAN) diagnostic tests in the absence of a gold standard, and assess CAN prevalence in our dataset. Setting Community and hospital health centre. Participants Of 2092 subjects available for data analysis, 371 healthy subjects were selected so the reference values for the short-term HRV test could be evaluated. An external dataset contained 88 subjects who completed both the short-term HRV test and Ewing's test. Intervention Collection of information on clinical outcome. Primary and second outcome measures Cardiovascular autonomic function evaluated by using the short-term HRV test and/or Ewing's test. Results Cut-off points of 356.13, 55.45 and 36.64?ms2 were set for total power, low frequency and high frequency (HF), respectively. The diagnostic test for CAN based on the mentioned reference value was created. The HRV test had a high sensitivity (80.01–85.09%) and specificity (82.30–85.20%) for CAN. In addition, the non-inferiority test rejected the null hypothesis that the performance of the HRV test was inferior to that of Ewing's test (p0.05). The estimated CAN prevalence was 14.92% and 29.17% in the total sample and patients with diabetes, respectively. Conclusions Our findings provided reference values for short-term HRV, which were used for the CAN diagnostic test with high sensitivity and specificity. The estimated CAN prevalence was high in the Chinese population.
机译:目的评估短期心率变异性(HRV)的参考值,评估缺乏黄金标准的心血管自主神经病变(CAN)诊断测试的性能,并评估我们数据集中的CAN患病率。设置社区和医院保健中心。参加者在可用于数据分析的2092名受试者中,选择了371名健康受试者,因此可以评估短期HRV测试的参考值。外部数据集包含88位完成短期HRV测试和Ewing测试的受试者。干预收集有关临床结果的信息。主要和次要结局指标通过使用短期HRV测试和/或Ewing测试评估心血管自主功能。结果总功率,低频和高频(HF)的截止点分别设置为356.13、55.45和36.64?ms 2 。创建了基于上述参考值的CAN诊断测试。 HRV检测对CAN具有很高的敏感性(80.01–85.09%)和特异性(82.30–85.20%)。另外,非劣效性测试拒绝了HRV评估的性能低于尤因检验的无效假设(p <0.05)。在总样本和糖尿病患者中,估计的CAN患病率分别为14.92%和29.17%。结论我们的发现为短期HRV提供了参考值,这些参考值被用于CAN诊断测试,具有很高的灵敏度和特异性。在中国人口中,估计的CAN患病率很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号