首页> 外文期刊>Journal of Medical Physics/Association of Medical Physicists of India >Optimization of dose distribution with multi-leaf collimator using field-in-field technique for parallel opposing tangential beams of breast cancers
【24h】

Optimization of dose distribution with multi-leaf collimator using field-in-field technique for parallel opposing tangential beams of breast cancers

机译:使用多叶准直仪使用场内技术对平行平行的乳腺癌切向光束进行剂量分配的优化

获取原文
           

摘要

3 Dimensional Conformal Radiotherapy (3D-CRT) planning software helps in displaying the 3D dose distribution at different levels in the planned target volume (PTV). Physical or dynamic wedges are commonly applied to obtain homogeneous dose distribution in the PTV. Despite all these planning efforts, there are about 10% increased dose hot spots encountered in final plans. To overcome the effect of formation of hot spots, a manual forward planning method has been used. In this method, two more beams with multi-leaf collimator (MLC) of different weights are added in addition to medial and lateral wedged tangent beams. Fifteen patient treatment plans were taken up to check and compare the validity of using additional MLC fields to achieve better homogeneity in dose distributions. The resultant dose distributions with and without presence of MLC were compared objectively. The dose volume histogram (DVH) of each plan for the PTV was evaluated. The 3D dose distributions and homogeneity index (HI) values were compared. The 3D dose maximum values were reduced by 4% to 7%, and hot spots assumed point size. Optimizations of 3D-CRT plans with MLC fields improved the homogeneity and conformability of dose distribution in the PTV. This paper outlines a method of obtaining optimal 3D dose distribution within the PTV in the 3D-CRT planning of breast cases.Keywords: 3D-CRT, dose volume histogram, homogeneity index, planned target volume
机译:3维保形放射治疗(3D-CRT)计划软件可帮助显示计划目标体积(PTV)中不同级别的3D剂量分布。通常使用物理或动态楔形以获得PTV中的均匀剂量分布。尽管进行了所有这些计划工作,但最终计划中遇到的剂量热点增加了约10%。为了克服热点形成的影响,已使用了手动前向计划方法。在这种方法中,除了内侧和外侧楔形切线光束之外,还添加了另外两个具有不同权重的多叶准直仪(MLC)的光束。制定了15个患者治疗计划,以检查和比较使用其他MLC字段以实现剂量分布中更好的同质性的有效性。客观地比较了有无MLC时所得的剂量分布。评估了每个PTV计划的剂量体积直方图(DVH)。比较了3D剂量分布和均一性指数(HI)值。 3D剂量最大值减少了4%至7%,并且热点均假定为点大小。利用MLC领域对3D-CRT计划进行的优化提高了PTV中剂量分布的均匀性和一致性。本文概述了一种在乳腺病例的3D-CRT规划中获得PTV内最佳3D剂量分布的方法。关键词:3D-CRT,剂量体积直方图,均匀性指数,计划目标体积

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号