首页> 外文期刊>Journal of Research in Dentistry >Quantitative and qualitative evaluation of resin-dentin bond strengths: in vitro effects of surface treatment with metalloproteinase inhibitors
【24h】

Quantitative and qualitative evaluation of resin-dentin bond strengths: in vitro effects of surface treatment with metalloproteinase inhibitors

机译:树脂和牙本质结合强度的定量和定性评估:金属蛋白酶抑制剂表面处理的体外影响

获取原文
           

摘要

AIM: The objective of this study was to evaluate the use of MMPs inhibitors (chlorhexidine and EDTA) in bond strength and quality of the hybrid layer of adhesive restorations in normal dentin using two ethanol-based total-etch adhesive systems. MATERIAL AND METHODS: Thirty-two extracted human molars were coronally sectioned and randomly divided into 8 groups (n=4), depending on the surface pre-treatment and adhesive system used. The total-etch adhesive systems Single Bond 2 (2-step) and Adper Scotchbond Multi-Purpose Plus (3-step) were used as follows: 1) according to manufacturer's instructions (etching with 37% phosphoric acid (H 3 PO 4 ) for 15 s); 2) etching with H 3 PO 4 for 15 s, followed by 2% chlorhexidine for 120 s; 3) etching with 0.1 M EDTA for 60 s; 4) etching with 0.1 M EDTA followed by 2% chlorhexidine for 120 s. Teeth were incrementally restored with composite resin (Filtek Z350XT). After water storage for 24 h, teeth were double-sectioned, yielding stick specimens of 1.0 mm2 bonded area, and then subjected to microtensile bond strength (MTBS) test at 0.5 mm/min. Additional specimens were gold-sputtered to be analyzed under scanning electron microscopy (SEM). Data (in Mega Pascal) were subjected to Kruskal-Wallis and Dunn (p <0.05) tests. RESULTS: The etching protocol (37% H 3 PO 4 or EDTA) interfered with hybrid layer formation, monomer penetration and the MTBS. Funnel shaped resin tags were observed when dentin was etched with 37% H 3 PO 4 . In these specimens, MTBS were also higher. EDTA conditioning produced thin hybrid layers and smaller MTBS, regardless the adhesive system used. Chlorhexidine application after conditioning resulted in no apparent differences between both evaluated techniques (37% H 3 PO 4 or EDTA). CONCLUSION: The use of chlorhexidine as a MMP inhibitor does not alter immediate bond strength values and does not interfere with hybrid layer formation.
机译:目的:本研究的目的是评估使用两种基于乙醇的全蚀刻胶粘剂系统在正常牙本质中胶粘剂修复体混合层的粘结强度和质量中使用MMPs抑制剂(洗必泰和EDTA)的情况。材料与方法:将32颗提取的人类臼齿进行冠状切片,并随机分为8组(n = 4),具体取决于表面预处理和所用的粘合剂体系。总蚀刻粘合剂系统Single Bond 2(2步)和Adper Scotchbond Multi-Purpose Plus(3步)的使用方法如下:1)根据制造商的说明(用37%的磷酸(H 3 PO 4)进行蚀刻)。持续15 s); 2)用H 3 PO 4蚀刻15 s,然后用2%洗必泰蚀刻120 s; 3)用0.1M EDTA蚀刻60秒; 4)用0.1 M EDTA蚀刻,然后用2%洗必泰蚀刻120 s。用复合树脂(Filtek Z350XT)逐渐修复牙齿。储水24小时后,将牙齿切成两半,得到1.0 mm2粘结面积的棒状试样,然后以0.5 mm / min的速度进行微拉伸粘结强度(MTBS)测试。将其他样品溅射金,以便在扫描电子显微镜(SEM)下进行分析。数据(以兆帕斯卡计)接受了Kruskal-Wallis和Dunn(p <0.05)检验。结果:蚀刻方案(37%H 3 PO 4或EDTA)会干扰杂化层的形成,单体渗透和MTBS。当牙本质用37%H 3 PO 4蚀刻时,观察到漏斗状的树脂标签。在这些标本中,MTBS也较高。 EDTA调理产生薄的混合层和较小的MTBS,而与所使用的粘合剂体系无关。调理后施用洗必泰在两种评估技术之间均无明显差异(37%H 3 PO 4或EDTA)。结论:使用洗必泰作为MMP抑制剂不会改变即时键强度值,也不会干扰杂化层的形成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号