首页> 外文期刊>Microscopy research and technique >Micromorphology and Bond Strength Evaluation of Adhesive Interface of a Self-Adhering Flowable Composite Resin-Dentin: Effect of Surface Treatment
【24h】

Micromorphology and Bond Strength Evaluation of Adhesive Interface of a Self-Adhering Flowable Composite Resin-Dentin: Effect of Surface Treatment

机译:自粘性可流动复合树脂-牙本质粘合界面的微观形貌和粘合强度评估:表面处理的影响

获取原文
获取原文并翻译 | 示例
       

摘要

This study evaluated the effect of dentin surface treatment on the micromorphology and shear bond strength (SBS) of a self-adhering flowable composite, Vertis Flow (VF). Flat dentin surfaces obtained from sixty extracted human molars were divided into six groups (n=10) according to the following surface treatments: (G1) control, no treatment; (G2) self-etching adhesive, Optibond All-in-One; (G3) phosphoric acid etching for 15 s; (G4) polyacrylic acid for 10 s; (G5) EDTA for 60 s; and G6) sodium hypochlorite (NaOCl) for 15 s. After restoration using VF, SBS was measured in MPa. Data were analyzed using one-way ANOVA and Tamhane test (alpha=0.05). Six additional specimens were prepared for scanning electron microscopy analysis. SBS was significantly affected by surface treatment (P<0.001). SBS of six groups from the highest to the lowest were as follows: (G3) 13.5(A); (G5) 8.98(AB); (G2) 8.85(AB); (G4) 8.21(AB); (G1) 7.53(BC); and (G6) 4.49(C) (groups with the same superscript letter were statistically similar). Morphological analysis revealed numerous long resin tags at the adhesive interface for acid-etched group, with a few short resin tags for the control group and small gap formation for NaOCl-treated group. In conclusion, dentin surface treatments tested differently affected bonding performance of VF; only acid-etching effectively improved this. Microsc. (C) 2016 Wiley Periodicals, Inc.
机译:这项研究评估了牙本质表面处理对自粘可流动复合材料Vertis Flow(VF)的微观形态和剪切粘合强度(SBS)的影响。根据以下表面处理,将从60个提取的人类臼齿获得的平坦牙本质表面分为6组(n = 10):(G1)对照,不进行处理; (G2)自蚀刻胶,Optibond多合一; (G3)磷酸腐蚀15 s; (G4)聚丙烯酸10秒钟; (G5)EDTA持续60 s; G6)次氯酸钠(NaOCl)15秒钟。使用VF恢复后,以MPa为单位测量SBS。使用单向方差分析和Tamhane检验分析数据(alpha = 0.05)。制备了另外六个样品用于扫描电子显微镜分析。表面处理对SBS有显着影响(P <0.001)。从最高到最低的六个组的SBS如下:(G3)13.5(A); (G5)8.98(AB); (G2)8.85(AB); (G4)8.21(AB); (G1)7.53(BC); (G6)4.49(C)(具有相同上标字母的组在统计上相似)。形态学分析显示,酸蚀刻组的粘合剂界面处有许多长的树脂标签,对照组中有一些短的树脂标签,而NaOCl处理的组则形成了小的间隙。总之,测试的牙本质表面处理对VF的粘合性能有不同的影响。只有酸蚀有效地改善了这一点。 Microsc。 (C)2016威利期刊公司

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号