首页> 外文期刊>Journal of Veterinary Internal Medicine >Comparison of 2 differently sized endoscopic biopsy forceps in the evaluation of intestinal disease in cats
【24h】

Comparison of 2 differently sized endoscopic biopsy forceps in the evaluation of intestinal disease in cats

机译:两种不同尺寸的内镜活检钳在猫肠病评估中的比较

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background In clinical practice, histopathological diagnosis of chronic intestinal disease is challenging because of difficulty in obtaining adequate duodenal samples. At present, no studies have investigated the influence of biopsy forceps size on sample quality in cats. Objectives Duodenal biopsy using larger biopsy forceps (2.4?mm) will provide higher quality samples. Animals Fifty client‐owned cats underwent endoscopy of the upper gastrointestinal tract for evaluation of chronic gastrointestinal signs, with inflammatory bowel disease (IBD) or intestinal lymphoma as differential diagnoses. Methods For each cat, duodenal biopsy specimens were obtained using both small (1.8?mm) and large (2.4?mm) forceps and evaluated for adequacy, orientation, the presence of artifacts, villi morphology, the presence of inflammation, and neoplastic infiltration. Results The percentage of adequate and evaluable biopsy specimens obtained using the larger forceps was significantly higher than that collected using the smaller forceps. Agreement between the forceps was variable for histological features and substantial in the case of lymphoma. However, in case of disagreement, the proper diagnosis usually was achieved only with the larger biopsy forceps. Conclusions and Clinical Importance Use of a larger biopsy forceps allows collection of a higher percentage of adequate and evaluable biopsy specimens compared to the commonly used smaller forceps and indirectly decreases the percentage of artifacts and increases the percentage of samples with evaluable villi. The use of a larger forceps could be helpful to obtain high‐quality samples and improve diagnostic accuracy.
机译:背景技术在临床实践中,由于难以获得足够的十二指肠样本,因此慢性肠道疾病的组织病理学诊断具有挑战性。目前,尚无研究调查活检钳大小对猫样品质量的影响。目的使用更大的活检钳(2.4?mm)进行十二指肠活检将提供更高质量的样本。动物对五十只家养的猫进行了上消化道内窥镜检查,以评估慢性胃肠道体征,并以炎症性肠病(IBD)或肠淋巴瘤作为鉴别诊断。方法对每只猫,使用小(1.8?mm)和大(2.4?mm)镊子获取十二指肠活检标本,并评估其充分性,方向,假象的存在,绒毛形态,炎症的存在和赘生性浸润。结果使用较大的钳子获得的足够且可评估的活检标本的百分比显着高于使用较小的钳子所收集的样本。镊子之间的一致性在组织学特征上是可变的,在淋巴瘤的情况下是实质性的。但是,如果出现分歧,通常只能使用较大的活检钳才能进行正确的诊断。结论和临床重要性使用较大的活检钳可以收集比通常使用的较小的钳更高的百分比的适当和可评估的活检标本,并间接减少伪影的百分比并增加可评估绒毛的样品的百分比。使用较大的镊子可能有助于获得高质量的样本并提高诊断准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号