ercial products. However, there is no standardized method for PRP preparation. Objective To evaluate the effect of different speeds of centrifugation on PRP preparation. Patients and methods A volume of 10 ml of whole venous blood was collected from 20 healthy volunteers (10 female and 10 male), aged 20a??40 years. These samples were divided into two tubes and left to precipitate (sample 1) and the platelet concentration was measured in the supernatant. The sample was then resuspended and the first tube was centrifuged at low speeds of 200, 300, and 500 rpm, and the second tube was centrifuged at 700, 900, 1100, and 3000 rpm (samples 2a??8, respectively) and the platelet concentration was measured and compared in the obtained PRP. Platelet concentration was measured in the two PRP samples obtained from two more volunteers (both male) using the commercial Regen kit and compared with those obtained by means of the laboratory method from samples obtained from the same volunteers. Results The platelet concentration was the highest in the PRP obtained in samples 1 and 2, followed by that obtained in samples subjected to lower speeds of centrifugation (300 and 500 rpm), and it was significantly higher compared with that obtained using a ready-to-use kit. Moreover, the white blood cell concentration was higher in the PRP obtained using laboratory method compared with that obtained using the kit method. Conclusion Laboratory preparation of PRP, especially that obtained without centrifugation, or using lower centrifugation speed, yields higher platelet concentration. Centrifugation at low speed is preferable as it saves time, avoids sample contamination, and preserves platelets....
机译:产品。但是,没有用于PRP制备的标准化方法。目的评价不同离心速度对PRP制备的影响。患者和方法从20岁至40岁的20位健康志愿者(10位女性和10位男性)收集了10毫升全静脉血。将这些样品分成两个试管并使其沉淀(样品1),并测量上清液中的血小板浓度。然后将样品重悬,将第一管以200、300和500 rpm的低速离心,将第二管以700、900、1100和3000 rpm离心(分别为样品2a-8)和测定血小板浓度,并与所得的PRP进行比较。使用商业Regen试剂盒测量了从另外两名志愿者(均为男性)获得的两种PRP样品中的血小板浓度,并将其与通过实验室方法从同一名志愿者获得的样品中的血小板浓度进行了比较。结果血小板浓度在样品1和2中获得的PRP最高,其次是在较低离心速度(300和500 rpm)下获得的PRP,与使用即用型获得的PRP相比,血小板浓度显着更高。使用套件。此外,与使用试剂盒方法获得的PRP相比,使用实验室方法获得的PRP中的白细胞浓度更高。结论实验室制备的PRP,特别是未经离心或使用较低离心速度获得的PRP,可产生较高的血小板浓度。优选低速离心,因为这样可以节省时间,避免样品污染并保存血小板...。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号