首页> 外文期刊>Journal of the human-environment system >Direct Determination of Local Evaporative Heat Transfer Coefficientsby Simultaneous Measurement of Local Sweat Rate and Evaporation Rate
【24h】

Direct Determination of Local Evaporative Heat Transfer Coefficientsby Simultaneous Measurement of Local Sweat Rate and Evaporation Rate

机译:通过同时测量局部出汗率和蒸发率直接确定局部蒸发传热系数

获取原文
           

摘要

In this study, local evaporation rates (msk) at chest, front thigh and forearm were measured with local calorimeters and local sweat rates (msw) were simultaneously measured with ventilated capsules at the same regions while a subject was exposed to the heat (46-48°C) for one hour. During the first 30-40 minutes, msk increased progressively with msw and became appreciably less than msw after the skin region was fully wetted with sweat. Thus, the critical msk value can be clearly identified during the heat exposure so as to determine local evaporative heat transfer coefficients. The results showed that the he values for chest, front thigh and forearm were 5.5, 6.1 and 7.3 (kcal/m2.h.mmHg), respectively.
机译:在这项研究中,使用局部热量计测量胸部,大腿前臂和前臂的局部蒸发率(msk),同时在相同区域使用通气胶囊同时测量局部出汗率(msw)(46- 48°C)1小时。在最初的30-40分钟内,msk随着msw的增加而逐渐增加,并且在皮肤区域被汗水完全浸湿后变得明显少于msw。因此,可以在热暴露期间清楚地识别出临界msk值,从而确定局部蒸发传热系数。结果显示,胸部,前大腿和前臂的he值分别为5.5、6.1和7.3(kcal / m2.h.mmHg)。