Direct measurement of the switching voltage between pre-breakdown and breakdown regions in the current-voltage ( I - V ) characteristics of zinc oxide varistors is difficult, and the varistor voltage is normally measured at 10-3 A as a reference current. In this study, using a simple I - V measurement system, the change in leak current associated with device degradation was measured to determine the switching voltage of commercial zinc oxide varistors. The switching voltage was found to be 45.3 V while the varistor voltage as determined from the I - V characteristics at a reference current of 10-3 A was 47.9 V. This new method can be effectively used for measuring the switching voltage of varistors.
机译:很难直接测量氧化锌压敏电阻的电流-电压(I-V)特性中的击穿前区域和击穿区域之间的开关电压,并且通常在10 -3 A下测量压敏电阻电压作为参考电流。在这项研究中,使用简单的I-V测量系统,测量了与器件退化相关的泄漏电流变化,以确定商用氧化锌压敏电阻的开关电压。发现开关电压为45.3 V,而在参考电流为10 -3 A时根据I-V特性确定的压敏电阻电压为47.9V。该新方法可有效地用于测量压敏电阻的开关电压。