>This study deals with B, S, and P determination in mineral fertilizer and S in commercial sulfur-formulation using inductively coupled plasma optical emission spectrometry. According to multivariate optimization using a Doehlert matrix, the analytes extraction in fertlizer can be conducted in open flask and heating on hot plate or in closed flask in microwave oven. However, when S is present in its elemental form in the fertilizer, the sample must be decomposed in closed flask in microwave oven for accurate S quantification. The uncertainties of the method were estimated according to the bottom-up approach, which were 7.1, 4.3, and 7.8% for B, S and P, respectively. The main sources of uncertainty identified were the intermediate precision, accuracy, regression of the calibration curve and errors originated from volumetric flasks and pipettes. Satisfactory results were obtained in the analysis of certified reference materials and sample from inter-laboratory programs as well as S recovery in a commercial elemental sulfur sample.
机译:>该研究涉及使用感应耦合等离子体光发射光谱法测定矿物肥料中B,S和P的含量以及商业化硫配方中S的含量。根据使用Doehlert矩阵进行的多变量优化,可以在开放式烧瓶中,在加热板上或在微波炉中的封闭烧瓶中加热的条件下,在肥料中提取分析物。但是,当肥料中以元素形式存在S时,必须将样品在微波炉的密闭烧瓶中分解才能准确地定量S。该方法的不确定性根据自下而上的方法进行估算,B,S和P分别为7.1、4.3和7.8%。所确定的不确定性的主要来源是中间精度,准确性,校准曲线的回归以及来自容量瓶和移液器的误差。在分析认证的参考物质和实验室间程序的样品以及商业元素硫样品中的S回收率方面均获得了令人满意的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号