Development and validation of a HPLC method for the determination of aldicarb, aldicarb sulfoxide and aldicarb sulfone in liquid samples from anaerobic reactors

机译:高效液相色谱法测定厌氧反应器液体样品中涕灭威,涕灭威亚砜和涕灭威砜的方法开发与验证

获取原文
           

摘要

This study describes the development and validation of a high-performance liquid chromatography (HPLC) method for detecting aldicarb and its residues in liquid samples without pretreatment. The HPLC system was equipped with a C-18 column and the mobile phase was composed of a mixture of water and acetonitrile using a linear gradient elution. The UV detector was utilized at 210 nm. Methomyl was used as an internal standard. Water and synthetic medium were used as solvents. The method was linear from 0.49-15.0 mg L-1 (r2 > 0.9985), 0.1-5.0 mg L-1 (r2 > 0.9974) and 0.1-5.0 mg L-1 (r2 > 0.9987) for aldicarb, aldicarb sulfoxide and aldicarb sulfone, respectively. The linearity of the method was confirmed by the ANOVA F-test through adjustment of the linear model, validity of the regression and efficiency of the regression tests. The limit of detection in water and synthetic medium were of 0.391/0.440 mg L-1, 0.069/0.192 mg L-1 and 0.033/0.068 mg L-1 for aldicarb, aldicarb sulfoxide and aldicarb sulfone, respectively. Total time of analysis was of 22 min. In the application of the method, the aldicarb degradation in horizontal-flow anaerobic immobilized biomass (HAIB) reactor was evaluated under different conditions (methanogenic, sulfidogenic and denitrifying).
机译:这项研究描述了无需预处理即可检测液体样品中涕灭威及其残留的高效液相色谱(HPLC)方法的开发和验证。 HPLC系统配有C-18色谱柱,流动相由水和乙腈的混合物组成,采用线性梯度洗脱。在210nm处使用UV检测器。灭多威用作内标。水和合成介质用作溶剂。对于涕灭威,涕灭威亚砜和涕灭威,该方法线性范围为0.49-15.0 mg L-1(r2> 0.9985),0.1-5.0 mg L-1(r2> 0.9974)和0.1-5.0 mg L-1(r2> 0.9987)砜,分别。通过调整线性模型,回归的有效性和回归测试的效率,通过方差分析F检验确认了该方法的线性。水和合成培养基中涕灭威,涕灭威亚砜和涕灭威砜的检出限分别为0.391 / 0.440 mg L-1、0.069 / 0.192 mg L-1和0.033 / 0.068 mg L-1。分析的总时间为22分钟。在该方法的应用中,在不同条件下(产甲烷,生硫和反硝化)评估了水平流厌氧固定生物质(HAIB)反应器中涕灭威的降解情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号