Stress-free lattice spacing d_(0) has the most influence on reliability of neutron stress measurements made using an angle dispersive method. However, it is hard to evaluate the lattice spacing of welded structures and ductile materials such as stainless steel accurately. In this study, suitable measurement conditions for d_(0) of welded pipe joints of austenitic stainless steel were discussed. The d_(0) values derived from {311} and {111} reflections, which are often used in austenitic stainless steel for residual stress measurement, were examined. Comparison of the residual strains and stresses evaluated using the obtained d_(0) and the finite element analysis showed that the way the d_(0) values were chosen affected the measurement accuracy significantly. The stress measurement accuracy was remarkably improved when the {311} reflection was used and the proper d_(0) value was chosen in the respective neutron diffraction measurements. For instance, for the axial diffraction measurements using the {311} reflection, it was recommended that only the axial d_(0) value of the {311} reflection be used; the measurements using the {111} reflection were less accurate due to the large Young's modulus. Additionally, a lower diffraction angle was judged to be one of the factors leading to a decrease of the strain measurement accuracy.
机译:无应力晶格间距 d_(0)对使用角分散法进行的中子应力测量的可靠性影响最大。但是,很难准确评估焊接结构和易延展材料(例如不锈钢)的晶格间距。在这项研究中,讨论了奥氏体不锈钢焊接管接头的d_(0)的合适测量条件。检查了源自{311}和{111}反射的 d_(0)值,这些反射常用于奥氏体不锈钢的残余应力测量中。使用获得的d_(0)和有限元分析对残余应变和应力进行比较,结果表明选择d_(0)值的方式会显着影响测量精度。当使用{311}反射并且在各个中子衍射测量中选择适当的Id_(0)值时,应力测量的精度显着提高。例如,对于使用{311}反射的轴向衍射测量,建议仅使用{311}反射的轴向 d_(0)值。由于大的杨氏模量,使用{111}反射进行测量的准确性较差。另外,较低的衍射角被认为是导致应变测量精度降低的因素之一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号