首页> 外文期刊>Journal of Residuals Science & Technology >Removal of Toxic Organic Pollutants from Coke Plant Wastewater by UV-Fenton
【24h】

Removal of Toxic Organic Pollutants from Coke Plant Wastewater by UV-Fenton

机译:UV-Fenton去除焦炭厂废水中的有毒有机污染物

获取原文
           

摘要

Coke plant wastewater containing lots of toxic organic pollutants should be treated before being discharged into the environment. It is challenging to treat toxic and refractory compounds using conventional methods. In this study, a UV-Fenton technology was investigated. When the initial COD, NH3-N concentration and SS of wastewater were 5080 mg/L, 329.9 mg/L, and 847.7 mg/L, results showed that the removal rate of COD, NH3-N and SS were 88.0%, 58.4% and 99.2% respectively under the optimal reaction conditions. Under the identified optimal condition, H2O2 concentration is 75 mmol/L, the concentration ratio of H2O2 and Fe2+ is 3:1, and original pH is 4 within 30 min. GC-MS analysis, revealed that organic substances such as indole and quinoline were degraded effectually.
机译:含有大量有毒有机污染物的焦化厂废水应先排放后再处理。使用常规方法处理有毒和难处理的化合物具有挑战性。在这项研究中,研究了紫外线芬顿技术。当初始COD,NH3-N浓度和SS分别为5080 mg / L,329.9 mg / L和847.7 mg / L时,结果表明,COD,NH3-N和SS的去除率分别为88.0%,58.4%。在最佳反应条件下分别为99.2%。在确定的最佳条件下,H2O2浓度为75 mmol / L,H2O2与Fe2 +的浓度比为3:1,原始pH在30分钟内为4。 GC-MS分析表明,吲哚和喹啉等有机物质被有效降解。