首页> 外文期刊>Journal of Residuals Science & Technology >A Study on Mechanism of Organic Matter Removal in a Three-step Series Constructed Rapid Infiltration System Used for Domestic Wastewater Treatment
【24h】

A Study on Mechanism of Organic Matter Removal in a Three-step Series Constructed Rapid Infiltration System Used for Domestic Wastewater Treatment

机译:三段式串联快速渗透系统处理生活污水中有机物去除机理的研究

获取原文
       

摘要

This study focused on domestic wastewater in a campus and investigated chemical oxygen demand (COD) removal efficiency and removal mechanism in a wastewater treatment system using three-step series constructed rapid infiltration (CRI). The experimental results indicated that the three-step series CRI system led to COD removal of 79.65%, a value 6% greater than that in a system using conventional CRI. Moreover, the effluent water quality of the three-step series CRI system met the first level criteria A as specified in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB18918-2002). Total organic matter and particulate organic matter in the wastewater were removed in the first compartment of the system by 54% and 83%, respectively. The quantity of aerobic ammonifying bacteria decreased from top to bottom along the compartments in the system, and was obviously higher than in the conventional CRI system. The dehydrogenase activity showed an M-shaped variation pattern in which two peak activity values were observed. The COD removal efficiency showed a very significant correlation with the aerobic bacteria quantity (correlation coefficient r = 0.97), and showed a relatively significant correlation with the dehydrogenase activity (r = 0.64). The biofilm mass and the active biofilm mass showed M-shaped variation patterns, and were obviously higher than in the conventional CRI system. The COD removal efficiency showed a relatively significant correlation with the weight of the active biofilm mass (r = 0.73).
机译:这项研究的重点是校园生活污水,并使用三步串联构造的快速渗透(CRI)研究了废水处理系统中化学需氧量(COD)的去除效率和去除机理。实验结果表明,三步串联CRI系统导致COD去除率为79.65%,比使用常规CRI的系统高出6%。此外,三步串联CRI系统的出水水质达到了《市政污水处理厂污染物排放标准》(GB18918-2002)中规定的一级标准A。在系统的第一个隔室中,废水中的总有机物和颗粒有机物分别被去除了54%和83%。有氧氨化细菌的数量沿系统的隔室从上到下减少,并且明显高于常规CRI系统。脱氢酶活性显示出M形变化模式,其中观察到两个峰活性值。 COD去除效率与需氧细菌数量显示非常显着的相关性(相关系数r = 0.97),与脱氢酶活性具有相对显着的相关性(r = 0.64)。生物膜质量和活性生物膜质量显示出M形变化模式,并且明显高于常规CRI系统。 COD去除效率与活性生物膜质量的重量表现出相对显着的相关性(r = 0.73)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号