Assessment of the Indoor Air Quality of Majors Biological Laboratories inOfrima Complex, University of Port-Harcourt, Nigeria

机译:尼日利亚哈科特大学Ofrima建筑群主要生物实验室的室内空气质量评估

获取原文
       

摘要

The study was carried out to assess the genera of airborne micro-organisms present in the indoor environment of Microbiology and Animal/Environmental Biology Majors’ laboratories in University of Port Harcourt; which could cause infection to laboratory users and contamination of culture. Indoor air was assessed (at 9 am, 12 pm and 4 pm) for five days and the basic parameters in this study were number of individuals present at each exposure time, time of sampling and duration. The settling plate technique was employed as sample collection method. The total heterotrophic bacterial and total fungal count from Microbiology Majors’ laboratory was 987 CFU/m2/h (Colony Forming Unit per square meters per hour) (80.18%) and 244 SFU/m2/h (Spore Forming Unit per square meters per hour) (19.82%) respectively while the total heterotrophic bacterial and total fungal count from Animal/Environmental Biology Majors’ laboratory was 677 CFU/m2/h (79.27%) and 177 SFU/m2/h (20.73%) respectively, reported as contamination flow. In the examined area, the predominant culturable species of air borne microflora were members of bacteria genera; Bacillus, Staphylococcus, Escherichia, Micrococcus, Pseudomonas, Serratia, Acinetobacter and fungi; Aspergillus, Cladosporium, Fusarium, Penicillium, Rhodotorula, Trichophyton, Candida, Mucor, Rhizopus, Scopulariopsis and Trichoderma. Despite the high number counted plates in both laboratories, the data proves to be statistically insignificant at P=0.05 for 9 am and 4 pm while significant at 12 noon for laboratories 1 and 2. Both laboratories are were undergraduate science students of the University of Port Harcourt in the faculty of biological sciences carry out their ressearch and study.
机译:这项研究旨在评估哈科特港大学微生物学和动物/环境生物学专业实验室的室内环境中存在的空气传播微生物的属;这可能会导致实验室使用者受到感染并污染培养物。在五天的时间内(分别在上午9点,中午12点和下午4点)对室内空气进行了评估,这项研究的基本参数是每次暴露时间,采样时间和持续时间中的个体人数。采用沉降板技术作为样品收集方法。来自微生物学专业实验室的异养细菌总数和真菌总数为987 CFU / m2 / h(菌落形成单位/平方米/小时)(80.18%)和244 SFU / m2 / h(孢子形成单位/平方米/小时) )(19.82%),而动物/环境生物学专业实验室的异养细菌总数和真菌总数分别为677 CFU / m2 / h(79.27%)和177 SFU / m2 / h(20.73%),据报告为污染流。在检查区域,气传微生物菌群的主要可培养种类是细菌属。芽孢杆菌,葡萄球菌,大肠埃希菌,微球菌,假单胞菌,沙雷氏菌,不动杆菌和真菌;曲霉,枝状孢子,镰刀菌,青霉,杜鹃花,毛癣菌,念珠菌,Mucor,根霉,鞘脂和木霉。尽管两个实验室中的板数均很高,但事实证明,在上午9点和下午4点的P = 0.05时,该数据在统计学上不显着,而在实验室1和2的中午12点时,该数据是有意义的。这两个实验室都是港口大学的大学理科学生生物科学院的Harcourt进行研究和研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号