Comparative Assessment of Force Decay of the Elastomeric Chain With the Use of Various Mouth Rinses in Simulated Oral Environment: An In Vitro Study

机译:在模拟的口腔环境中使用各种漱口水对弹性链的力衰减的比较评估:一项体外研究

获取原文
           

摘要

Aim: This study is aimed to assess the effect of different mouth rinses and its active components on the force decay of elastomeric chains. Listerine, Colgate Phos-Flur, Clohex Plus mouth rinses, 26.9% alcohol, 0.04% sodium fluoride (NaF), and 0.2% chlorhexidine were used for this study to determine its effects on force decay of elastomeric chains. Materials and Methods: Seven custom-made jigs were constructed on which 120 short module elastomeric chains were stretched to predetermined lengths between the pins. Using calibrated digital force tester, measurements of force exerted by the elastomeric chains while stretched on the framework were recorded at the time of attachment to the frame and after 24 hours, 7 days, 14 days, 21 days, and 28 days. The custom-made jigs and the elastomeric chains were allowed for complete submersion in artificial saliva throughout the test period, as well as in respective control solution and mouth rinses for 60 seconds, twice daily. Results: All test groups showed significantly more force decay than the control group. Statistically significant differences were observed when comparing force decay among the test groups except between a few. Interpretation and Conclusion: Mouth rinses cause an increase in force decay of elastomeric chain over the time. Listerine and 26.9% alcohol solution caused maximum force decay by the end of 28 days. Least force degradation of elastomeric chain was seen with the use of 0.2% chlorhexidine.
机译:目的:本研究旨在评估不同漱口水及其有效成分对弹性链衰减的影响。本研究使用李斯特德林,高露洁Phos-Flur,Clohex Plus漱口水,26.9%的酒精,0.04%的氟化钠(NaF)和0.2%的洗必泰确定其对弹性体链力衰减的影响。材料和方法:构建了七个定制夹具,在其上的120个短模块弹性链在销钉之间拉伸至预定长度。使用校准的数字力测试仪,在连接到框架时以及在24小时,7天,14天,21天和28天之后,记录弹性链在框架上拉伸时施加的力的测量值。在整个测试期间,允许定制的夹具和弹性体链完全浸入人工唾液中,以及分别浸入对照溶液和漱口水中60秒,每天两次。结果:所有测试组均显示出比对照组明显更多的力衰减。比较几个测试组之间的力衰减时,观察到统计学上的显着差异,除了少数几个之间。解释和结论:漱口随着时间的流逝会导致弹性链的力衰减增加。李斯特林和26.9%的酒精溶液在28天结束时引起最大的力衰减。使用0.2%的洗必太可观察到弹性链的最小力降解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号