首页> 外文期刊>Journal of Physics: Conference Series >Beam Based Measurement of Injection Parameters at KEKPF
【24h】

Beam Based Measurement of Injection Parameters at KEKPF

机译:基于光束的KEEKF注射参数测量

获取原文
           

摘要

Photon Factory storage ring (PF-ring) is the 2.5 GeV synchrotron radiation light source in KEK. After the earthquake hit in 2011, the injection efficiency using the conventional pulsed kicker and septum system has decreased. The primary cause of the problem seems to be the change of the injection parameters. To analyze the present injection parameter, we carried out the simulations [1] and beam studies. In this paper, we show the beam based estimation of the position and divergence angle of the injected beam at the exit of the injection septum magnet.
机译:光子工厂存储环(PF环)是KEK中的2.5 GeV同步加速器辐射光源。在2011年地震发生后,使用常规脉冲喷射器和隔垫系统的注射效率有所下降。问题的主要原因似乎是注射参数的变化。为了分析当前的注入参数,我们进行了模拟[1]和射束研究。在本文中,我们显示了基于离子束的位置估计和在注入隔片磁体出口处注入束的位置和发散角。