首页> 外文期刊>Journal of Physics: Conference Series >Response of Asymmetric Slim Floor Beams in Parametric-Fires
【24h】

Response of Asymmetric Slim Floor Beams in Parametric-Fires

机译:参数火灾中非对称超薄楼板梁的响应

获取原文
   

获取外文期刊封面封底 >>

       

摘要

State-of-the-art slim floor systems are a newest addition to the composite construction industry and several types are currently being used for building and construction purposes. Asymmetric slim floor beams are a type of slim floor systems which consist of a rolled section with a larger bottom flange. The larger bottom flange induces asymmetry and offers an efficient use of the material strength as a composite beam. It also offers a larger area to support the steel decking and pre-cast slab units during the construction of floor. Experimental and analytical investigations on response of asymmetric slim floor beams have shown that these beams offer a higher fire resistance in comparison to the conventional composite systems with down-stand steel beams. Previous investigations on these beams have been conducted in standard fire exposure conditions, hence, their response to natural fire scenarios still deems further examination. This study addresses response of asymmetric slim floor beams in natural fire exposure conditions. For this purpose, finite element models developed and verified by the authors are employed to study the thermal and structural response of slim floor beams in fast and slow parametric-fire exposures. Results obtained show that the asymmetric slim floor beams behave differently in parametric-fires in comparison to that in standard fire exposure conditions. Asymmetric slim floor beams continued to support the loads for the whole duration of parametric fires without undergoing excessive deflections and offering a better fire resistance. Unlike in case of the standard fire where the temperatures keep on increasing throughout the duration, temperatures on the slim floor beams decrease after reaching a maximum point in parametric-fires. It was found that for fast parametric-fires, the thermal gradient across the section is more severe as compared to that for the slow parametric-fires at earlier stages of fire exposure. In case of the fast parametric-fires, the rise and fall of temperatures on the slim floor beams are rapid while in case of the slow parametric-fire, these variations in temperatures are subtle. It was observed that the structural response of slim floor beams in standard and parametric fires depends on the average temperature across the steel section. Deflections predicted for the beams were found to be directly related to these average temperatures. Outcomes of this study will benefit in understanding the response of asymmetric slim floor beams in natural fire conditions and will aid to develop simple fire design methods for future use.
机译:最先进的超薄地板系统是复合建筑行业的最新成员,目前有几种类型的建筑和建筑用途。不对称的超薄地板横梁是一种超薄地板系统,其由具有较大底部凸缘的卷制部分组成。较大的底部凸缘引起不对称,并有效地利用了材料强度作为复合梁。它还提供了更大的区域,以在地板施工期间支撑钢质装饰板和预制板单元。对不对称细长地板横梁的响应进行的实验和分析研究表明,与具有竖立钢梁的传统复合系统相比,这些横梁具有更高的耐火性。以前已经在标准的火灾暴露条件下对这些光束进行了研究,因此,它们对自然火灾情况的响应仍然值得进一步检查。这项研究解决了自然火暴露条件下非对称细长地板梁的响应。为此,作者开发和验证的有限元模型被用于研究薄壁楼板在快速和慢速参数火灾中的热响应和结构响应。获得的结果表明,与标准的火灾暴露条件相比,非对称细长地板梁在参数火灾中的行为有所不同。不对称的超薄楼板梁在整个参数火灾期间持续支撑载荷,而不会发生过度挠曲并提供更好的耐火性。与标准火灾不同,在整个过程中温度持续升高,而在参数化火灾中达到最高点后,薄型地板梁上的温度会降低。已经发现,对于快速参数火灾,与在火灾早期阶段的缓慢参数火灾相比,截面上的热梯度要严重得多。在快速参数化火灾的情况下,薄型地板梁上的温度上升和下降很快,而在缓慢参数化火灾的情况下,这些温度变化是微妙的。据观察,在标准和参数火灾中,细地板梁的结构响应取决于整个钢截面的平均温度。发现对梁的预测挠度与这些平均温度直接相关。这项研究的结果将有助于理解非对称细长地板梁在自然火灾条件下的响应,并将有助于开发简单的火灾设计方法,以备将来使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号