References(2) Cited-By(2) The possibility of the practical use as an office lighting system, which make the total illuminance of 400lx and Task and Ambient illuminance ratio of 1.0 on the working desk, by using Task and Ambient Lighting system was reported on the last year research. On this year research, the following aspects were indicated based on the analysis of the psychological queries after two weeks actual work in the specific illuminance level and Task and Ambient illuminance ratio. The illuminance level of 200lx on a working desk cause some psychological problem as room and desk area ‘darkness’ and illuminance level ‘unevenness’. These problems were improved when the illuminance level of 300lx was applied. And this analysis suggested that the Task and Ambient illuminance ratio shall be around 1.0. An approximately 20% saving energy can be achieved under this lighting system condition compared with the general office lighting system.
机译:参考文献(2)By-By(2)实际用作办公照明系统的可能性是,通过使用Task and Ambient Lighting系统,使总照度为400lx,工作台上的Task和Ambient照明比为1.0。报告了去年的研究。在今年的研究中,根据对特定照度水平和任务与环境照度比的实际工作两周后的心理询问的分析,指出了以下几个方面。在工作台上200lx的照度水平会引起一些心理问题,例如房间和办公桌区域“黑暗”和照度水平“不均匀”。当应用300lx的照度水平时,这些问题得到了改善。并且此分析表明任务和环境照度比应为1.0左右。与普通办公室照明系统相比,在这种照明系统条件下可以节省大约20%的能源。