References(12) This paper relates to a novel discharge lamp operating system proposed for energy optimization and saving of resources, which employs a powerful oscillator to supply reignition energy immediately after lamp current pause of each half cycle of a.c. source in order to realize sub-stantially the same source and lamp voltages. Features of the system are investigated by analogue computer simulation on the trial for single 4OWT12 fluorescent lamp operating circuit at 100V line comparing with that of conventional single winding choke at 200V line. The following are improvements expressed by approximate estimates.(1) Inductance value and the maximum energy stored in a ballast are decreased to one fifth and one fourth, respectively.(2) Ballast weight and loss become one fourth and one third, and these ratios for a conventional rapid-start ballast will become one eleventh and one fourth, respectively.(3) Total efficacy becomes 116 percent, and for the rapid-start ballast it will become 131 percent. Further, this will be much raised by the use of a particularly designed lamp.(4) Power factor becomes 89 percent in lag phase.
机译:参考文献(12)本文涉及一种用于能量优化和节省资源的新型放电灯操作系统,该系统采用一个强大的振荡器在交流电每个半周期的灯电流暂停后立即提供点火能量。为了实现基本上相同的电源电压和灯电压。通过模拟计算机仿真,在100V线路单4OWT12荧光灯工作电路与传统200V线路单绕组扼流圈的试验电路上,对该系统的功能进行了研究。以下是通过近似估算表示的改进:(1)电感值和镇流器中存储的最大能量分别降低到五分之一和四分之一。(2)镇流器的重量和损耗分别为四分之一和三分之一,并且这些比率常规快速启动镇流器的功率将分别达到其十一分之一和四分之一。(3)总效率变为116%,快速启动镇流器的总效率将变为131%。此外,使用特别设计的灯将大大提高这一点。(4)滞后阶段的功率因数变为89%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号