A New Clinical Design Measuring the Vertical Axial Rotation Through Tibial Shaft Resulting from Passive Knee and Subtalar Joints Rotation in Healthy Subjects: A Reliability Study

机译:测量健康受试者被动膝关节和距下关节旋转引起的通过胫骨轴垂直轴旋转的新临床设计:可靠性研究

获取原文
       

摘要

The main purposes of the study are to determine the intra-inter rater reliability of a new special designed clinical evaluation system; to measure the amount of the vertical axial rotation of the tibia resulting from passive rotation of knee and subtalar joints. To achieve this, the Measuring the Vertical Axial Rotation Tibial Shaft (MVARTS) system was designed. The system apparatus is applied to each knee and measured the vertical axial rotation of the tibia and subtalar rotations together. Fifty healthy subjects were examined using the suggested system. Two evaluators measured the tibial internal and external rotations, passively. The pure tibial rotation was also measured radiologically on the X-Ray in only 24 subjects. The intra and inter observer variation was calculated between 2.1 and 3.8 degrees with high correlation (0.84-0.98). There was no significant difference between intra and inter observers` results (p>0.05). On the other hand, amount of the internal combined rotations was lower than the external rotation (p<0.01). The radiological external pure tibial rotations are 19.8±6.2 deg (right), 17.0±4.6 deg (left) for the males whilst 28.7±4.0 deg (right), 23.0±5.3 deg (left) for the females. The difference between the male and female subjects was also seen to be significant (p<0.05). The results showed that the MVARTS system is an appropriate, noninvasive, fast to measure combined tibial and subtalar joint rotation in addition to be economically very efficient.
机译:该研究的主要目的是确定新设计的新型临床评估系统的内部评估者信度。测量由于膝关节和距骨关节被动旋转而导致的胫骨垂直轴向旋转量。为此,设计了“测量垂直轴向旋转胫骨轴(MVARTS)”系统。将系统设备应用于每个膝盖,并一起测量胫骨的垂直轴向旋转和距下旋转。使用建议的系统检查了五十名健康受试者。两名评估员被动地测量了胫骨的内部和外部旋转。还仅在X射线下通过放射学方法对24位受试者进行了纯胫骨旋转测量。观察者之间和观察者之间的差异被计算为介于2.1和3.8之间,且具有高度相关性(0.84-0.98)。内部和内部观察者的结果之间无显着差异(p> 0.05)。另一方面,内部组合旋转量小于外部组合旋转(p <0.01)。男性的放射学上纯净的胫骨旋转度为男性19.8±6.2度(左),左侧为17.0±4.6度,女性为28.7±4.0度(右),23.0±5.3度(左)。男性和女性受试者之间的差异也被认为是显着的(p <0.05)。结果表明,MVARTS系统不仅经济高效,而且是一种合适的,无创的,可快速测量胫骨和距骨联合旋转的装置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号