...
首页> 外文期刊>Journal of Medical Radiation Sciences >Improving education and supervision of Queensland X-ray Operators through video conference technology: A teleradiography pilot project
【24h】

Improving education and supervision of Queensland X-ray Operators through video conference technology: A teleradiography pilot project

机译:通过视频会议技术改善昆士兰州X射线操作员的教育和监督:一个远程放射照相试点项目

获取原文

摘要

Abstract Introduction X-ray Operator (XO) supervision in Queensland is performed by radiographers in a site removed from the XO site. This has historically been performed by telephone when the XO requires immediate help, as well as post-examination through radiographer review and the provision of written feedback on images produced. This project aimed to improve image quality through the provision of real-time support of XOs by the introduction of video conference (VC) supervision. Methods A 6-month pilot project compared image quality with and without VC supervision. VC equipment was installed in the X-ray room at two rural sites, as well as at the radiographer site, to enable visual and oral supervision. The VC unit enabled visualisation of the X-ray examination technique as it was being undertaken, as well as the images produced prior to transmission to the Picture Archiving and Communication System (PACS). Results Statistically significant improvement in image quality criteria measures were seen for patient positioning ( P = 0.008), image quality ( P < 0.001) and diagnostic value ( P < 0.001) of images taken during this project. No statistically significant differences were seen during case level assessment in the inclusion of only appropriate imaging ( P = 0.06), and the inclusion of unacceptable imaging ( P = 0.06), however improvements were seen in both of these criteria. The survey revealed 24.6% of examinations performed would normally have involved the XO contacting the radiographer for assistance, although, assistance was actually provided in 88.3% of examinations. Conclusion This project has demonstrated that significant improvement in image quality is achievable with VC supervision. A larger study with a control arm that did not receive direct supervision should be used to validate the findings of this study.
机译:摘要简介昆士兰州的X射线操作员(XO)监督是由放射线技师在从XO站点移走的站点中进行的。过去,这是在XO需要即时帮助时通过电话进行的,以及通过放射线照相者的审查和对所产生图像的书面反馈来进行事后检查。该项目旨在通过引入视频会议(VC)监督来提供XO的实时支持,从而提高图像质量。方法一个为期6个月的试点项目比较了有无VC监督的图像质量。 VC设备安装在两个农村站点的X射线室以及射线照相站点,以实现视觉和口头监督。 VC单元使正在进行的X射线检查技术以及在传输到图片存档和通信系统(PACS)之前产生的图像可视化。结果在该项目期间拍摄的图像,对患者定位(P = 0.008),图像质量(P <0.001)和诊断值(P <0.001)的图像质量标准进行了统计上的显着改善。在病例水平评估期间,仅包括适当的影像学检查(P = 0.06)和包括不可接受的影像学检查(P = 0.06),在统计学上没有发现显着差异,但是,在这两个标准上均看到了改善。调查显示,通常有24.6%的检查会涉及XO与射线照相师联系以寻求帮助,尽管实际上有88.3%的检查提供了帮助。结论该项目证明了通过VC监督可以实现图像质量的显着改善。应当使用未经直接监督的对照组进行的较大研究,以验证该研究的结果。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号