The paper presents analysis of the availability of medium firefighting and rescue vehicles chassis used by State Fire Brigade in Warsaw. For analysis of availability of vehicles chassis the technical availability factor has been used. Additionally, in the paper time to restore of the vehicles chassis regarding causes of unavailability has been presented. In the tests the data obtained from the Decision Support System (DSS) of Warsaw State Fire Brigade were applied. The research included the period from January 2012 to May 2015. Based on the results, it can be statement that the operating mileage is the crucial factor of operating degradation of firefighting vehicles chassis.
机译:本文介绍了由华沙国家消防队使用的中型灭火和救援车辆底盘的可用性分析。为了分析车辆底盘的可用性,使用了技术可用性因子。另外,在本文中,提出了关于不可用原因的车辆底盘恢复的时间。在测试中,使用了从华沙国家消防队的决策支持系统(DSS)获得的数据。研究包括2012年1月至2015年5月。根据结果,可以得出结论,行驶里程是导致消防车底盘运行性能下降的关键因素。