...
首页> 外文期刊>Journal of Indian Society of Pedodontics and Preventive Dentistry >Comparative evaluation of fluoride release from hydroxyapatite incorporated and conventional glass ionomer cement: An in vitro study
【24h】

Comparative evaluation of fluoride release from hydroxyapatite incorporated and conventional glass ionomer cement: An in vitro study

机译:从掺入的羟基磷灰石和常规玻璃离聚物水泥中释放氟的比较评估:一项体外研究

获取原文
           

摘要

Background: Glass ionomers are most commonly used esthetic restorative material, but has inferior mechanical properties. The search to improve its mechanical properties led to the use of hydroxyapatite (HA) whiskers as strengthening material for glass ionomer cement but its effect on fluoride release is still not clear. Aims: To evaluate and compare the fluoride release from HA incorporated glass ionomer and conventional glass ionomer cement (CGIC). Settings and Design: This in vitro study comprised of total forty sample. Twenty Specimens of each HA incorporated glass ionomer and conventional glass ionomer were fabricated. Materials and Methods: Specimens were suspended individually in 25 mL of distilled water in a 50 mL plastic container and stored at 37°C. Distilled water was renewed every 24 h for 21 days. Fluoride release of sample was measured every 24 h for 7 days and weekly from 7 th day to 21 st day using Sension4 pH/ion selective electrode/mV meter. Statistical Analysis Used: Descriptive statistics, Repeated Measure analysis of variance, Paired Sample t-test, Independent Sample t-test, scheffe post hoc test. Results and Conclusion: There was a significant decrease in the mean fluoride release from day 1 to day 21 for both the groups hydroxyapatite glass ionomer cement and conventional glass ionomer cement ([HA-GIC] and CGIC). Though, the mean values of HA-GIC were slightly lower than C GIC, there was no statistically significant difference in the mean fluoride release between HA-GIC and CGIC throughout the experimental period. Within the limitations of this experimental design, definitive conclusions cannot be drawn and further investigations at a molecular level are needed to evaluate the trend of fluoride release from this material.
机译:背景:玻璃离聚物是最常使用的美学修复材料,但机械性能较差。为了提高其机械性能,人们寻求使用羟基磷灰石(HA)晶须作为玻璃离聚物水泥的增强材料,但其对氟化物释放的影响尚不清楚。目的:评估和比较掺入HA的玻璃离聚物和常规玻璃离聚物水泥(CGIC)中的氟化物释放量。设置和设计:这项体外研究包括40个样本。制备了每种掺有HA的玻璃离聚物和常规玻璃离聚物的二十个样品。材料和方法:将样品分别悬浮在50 mL塑料容器中的25 mL蒸馏水中,并保存在37°C下。每24小时更新一次蒸馏水,持续21天。使用Sension4 pH /离子选择电极/ mV测量仪,从第7天至第21天,每7天和每24小时测量一次氟化物的释放。使用的统计分析:描述性统计,方差的重复测量分析,配对样本t检验,独立样本t检验,scheffe事后检验。结果与结论:从第1天到第21天,羟基磷灰石玻璃离聚物水泥和常规玻璃离聚物水泥([HA-GIC]和CGIC)的平均氟化物释放量均显着下降。虽然,HA-GIC的平均值略低于C GIC,但在整个实验期间,HA-GIC和CGIC之间的平均氟化物释放量没有统计学上的显着差异。在此实验设计的限制内,无法得出明确的结论,需要在分子水平上进行进一步研究以评估氟化物从该材料释放的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号