Retrofitting materials like aluminum bars, steel laminates and glass fiber compounds has been used in the construction field for many decades. Carbon fiber compounds are the recent addition to the retrofitting materials. This study is a comparison of flexural and shear strength of a retrofitted beams with conventional beam. It also compares the experimental results with the analytical results. Analysis is done using the software ANSYS workbench. Carbon fiber fabric wraps are used for retrofitting test beams. Epoxy resin is used to bind the fabric to the beam in u – shaped wraps which binds the flexural face and the web of the beam. Total number of 4 beams of size (1500 × 200 × 250) mm including conventional beam is used for the experimental tests ( Two point loading). Difference in ultimate load, criticalload,flexural strength and shear strength are observed in experimental tests, and are being compare with analytical results. The beams were wrapped with five layers of carbon fiber fabric strips of different widths, 300 mm, 250 mm and 200 mm respectively. The highest flexural strength was observed in the two point load testing of beam retrofitted with 300 mm wide strips (BU30).
机译:诸如铝条,钢层压板和玻璃纤维混合物之类的翻新材料已在建筑领域中使用了数十年。碳纤维化合物是近来加装材料。这项研究是将改造后的梁与常规梁的抗弯强度和抗剪强度进行比较。它还将实验结果与分析结果进行了比较。使用软件ANSYS工作台进行分析。碳纤维织物包裹物用于改装测试梁。环氧树脂用于以u形包裹物将织物粘结到梁上,从而包裹弯曲面和梁的腹板。包括常规光束在内的4个尺寸为(1500×200×250)mm的光束总数用于实验测试(两点加载)。在实验测试中观察到极限载荷,临界载荷,弯曲强度和剪切强度的差异,并将其与分析结果进行比较。横梁用五层宽度分别为300 mm,250 mm和200 mm的碳纤维织物条包裹。在加装300 mm宽条(BU30)的梁的两点载荷测试中,观察到最高的弯曲强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号