摘要

This paper presents the design of the arc fault detection circuit that is able to detect three different signals prior to the occurrence of an arcing fault in the low voltage switchboard. There are pressure, heat and light signals. The simulation results show that the proposed arc fault detection circuit will activate the relay and send a trip signal to the circuit breaker if the illumination level in the interior of the low voltage (LV) switchboard is more than a predetermined value and at the same time both the pressure and temperature detectors detect a pressure and temperature level which are higher than the reference value. This is to ensure that no fault tripping signal is sent to the circuit breaker and therefore avoid unnecessary power shut down.
机译:本文提出了一种电弧故障检测电路的设计,该电路能够在低压配电盘中发生电弧故障之前检测三种不同的信号。有压力,热和光信号。仿真结果表明,所提出的电弧故障检测电路将在低压配电柜内部的照明水平大于预定值的同时,激活继电器并将跳闸信号发送至断路器。压力和温度检测器都检测到高于参考值的压力和温度水平。这是为了确保不会将故障跳闸信号发送到断路器,从而避免不必要的电源关闭。