首页> 外文期刊>Journal of Gynecological Endoscopy and Surgery >Do New Vessel Sealing Devices and Harmonic Ace Increase Ureteric Injury in Total Laparoscopic Hysterectomy?
【24h】

Do New Vessel Sealing Devices and Harmonic Ace Increase Ureteric Injury in Total Laparoscopic Hysterectomy?

机译:新的血管密封装置和谐波Ace是否会增加全腹腔镜子宫切除术中的输尿管损伤?

获取原文
       

摘要

Objectives:To compare the risk of ureteric injury in total laparoscopic hysterectomy (TLH) using new vessel sealing devices (VSDs) and harmonic scalpel with simple scissors, bipolar and suturing. This was an evaluation of 1209 cases, carried out from May 1999 to April 2010.Design and Setting:A retrospective comparative study was carried out at a tertiary gynecological endoscopic unit.Materials and Methods:Out of 1209 patients, who had hysterectomies for various indications, TLH was done in 892 patients, 273 had vaginal hysterectomy and 44 had abdominal hysterectomy. We evaluated the incidence of ureteric injury in these cases.Results:There was no mortality. In the group of vaginal and abdominal hysterectomy, there were no ureteric injuries. In the TLH group, we had 390 cases with simple scissors, bipolar and suturing with no ureteric injury. In 502 cases, new VSDs, e.g., plasma kinetic gyrus, Martin Maxim with Robi grasper, with or without harmonic 5 mm scalpel/ace were used. There were five ureteric injuries, all on the right side (one double ureter): first case was with Martin Maxim and Robi grasper, two with plasma kinetic gyrus 10 mm trissector, one with harmonic scalpel and the last one with scissors. We evaluated the reasons for such ureteric injuries, with experienced laparoscopic surgeons and the best possible set up. There were seven conversions to open surgery out of 892 cases of TLH, more due to poor case selection.
机译:目的:比较使用新型血管密封装置(VSD)和简单的剪刀,双极和缝合的谐波手术刀在全腹腔镜子宫切除术(TLH)中发生输尿管损伤的风险。这是对1999年5月至2010年4月进行的1209例病例的评估。设计与设置:在三级妇科内窥镜科进行回顾性比较研究。材料与方法:1209例患有各种适应症的子宫切除术患者892例患者接受了TLH手术,其中273例接受了阴道子宫切除术,而44例进行了腹部子宫切除术。我们评估了这些病例中输尿管损伤的发生率。结果:无死亡率。在阴道和腹部子宫切除术组中,没有输尿管损伤。在TLH组中,我们有390例患者使用了简单的剪刀,双极和缝合法,没有输尿管损伤。在502例病例中,使用了新的VSD,例如血浆动力学回旋仪,带Robi抓紧器的Martin Maxim,有无谐波5 mm手术刀/ ace。有5例输尿管损伤,全部在右侧(1例为双输尿管):第一例为Martin Maxim和Robi抓紧器,两例为血浆动能回旋10 mm三切肌,一例为谐波解剖刀,最后一例为剪刀。我们通过经验丰富的腹腔镜外科医生和最佳的设置来评估造成输尿管损伤的原因。 892例TLH患者中有7例转为开腹手术,更多是由于病例选择不佳。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号