首页> 外文期刊>Journal of Equine Science >Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares
【24h】

Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares

机译:PATHFAST化学发光酶免疫测定法测定母马全血和血清中的孕酮的评估

获取原文

摘要

Evaluation of a new chemiluminescent enzyme immunoassay, the PATHFAST assay system (PATHFAST), for measurement of circulating progesterone in mares was performed. Five mares at the mid-luteal stage were administrated a single i.m. injection of prostaglandin F2α analog (PGF2α; cloprostenol 250 μg/ml), and then blood samples were collected from the jugular vein at 0, 15, 30 and 45 min, at one-hour intervals until 24 and at 48 hr via a catheter in the jugular vein. To monitor the physiological changes in circulating progesterone in mares after induced luteolysis, concentrations of progesterone in whole blood and serum samples were measured by PATHFAST. In addition, concentrations of progesterone in serum samples measured by PATHFAST were compared with those measured by radioimmunoassay (RIA) and enzyme immunoassay (EIA). Using PATHFAST, the serum concentrations of progesterone in mares correlated highly with those of whole blood samples (r=0.9672, n=88). The serum concentrations of progesterone as measured by PATHFAST correlated well with RIA (r=0.9654, n=88) and EIA (r=0.9323, n=112). An abrupt decline in circulating progesterone in whole blood samples was observed within 2 hr (50%), followed by a gradual decline until 48 hr later. The results for progesterone in whole blood samples correlated highly with those in serum samples, and the declining pattern paralleled that of the serum samples. These results demonstrated that PATHFAST is useful in the equine clinic as an accurate diagnostic tool for rapid assay of progesterone within 26 min, using unextracted whole blood.
机译:评估了一种新的化学发光酶免疫测定法,即PATHFAST测定系统(PATHFAST),用于测量母马中的循环孕酮。黄体中期阶段的五只母马在一次i.m.注射前列腺素F2α类似物(PGF2α;氯前列醇250μg/ ml),然后在0、15、30和45分钟,每1小时间隔直到24和48小时通过导管从颈静脉采血颈静脉。为了监测诱导的黄体溶解后母马中循环孕酮的生理变化,通过PATHFAST测量了全血和血清样品中孕酮的浓度。此外,将通过PATHFAST测定的血清样品中的孕酮浓度与通过放射免疫测定(RIA)和酶免疫测定(EIA)测定的浓度进行了比较。使用PATHFAST,母马中的孕酮血清浓度与全血样本的浓度高度相关(r = 0.9672,n = 88)。通过PATHFAST测量的孕酮血清浓度与RIA(r = 0.9654,n = 88)和EIA(r = 0.9323,n = 112)很好地相关。在2小时内(50%)观察到全血样品中循环孕酮的突然下降,然后逐渐下降直到48小时。全血样品中的孕酮结果与血清样品中的结果高度相关,下降方式与血清样品中的方式平行。这些结果表明,PATHFAST在马临床中可用作准确的诊断工具,可使用未提取的全血在26分钟内快速测定孕酮。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有