Performance evaluation of reverse osmosis technology for selected antibiotics removal from synthetic pharmaceutical wastewater

机译:反渗透技术从合成制药废水中去除某些抗生素的性能评估

获取原文
       

摘要

This study addresses the possibility for low pressure reverse osmosis membrane (RE 2521, CSM) process to serve as an alternative to remove selected antibiotics (ampicillin and amoxicillin) from synthetic wastewater by changing operating conditions such as pH = 3, 6.5 and 10; Pressure = 9, 11 and13 (bar); antibiotic concentration = 10, 255 and 500(mg/L), and temperature = 20, 30 and 40°C. The experiment was designed based on Box-benken, which is a Response Surface methodology design (RSM), using Design Expert software. The concentration of antibiotics was measured by applying a UV-spectrophotometer (Cecil), at the wavelength of 254 nm. Results showed a range of rejection percentage from 73.52% to 99.36% and 75.1% to 98.8%, for amoxicillin and ampicillin, respectively. Considering the solute rejections and the membrane porosity show that the prevailing rejection mechanism of the examined antibiotics by the membrane was the size exclusion effect. The permeate flux for both of the antibiotics was 12–18.73 L/m2.h. Although the permeate flux and antibiotic rejection are influenced by operating pressure, pH, and temperature individually, the interaction between operating parameters did not have noticeable effects. According to the results obtained in this study, the application of RO membrane is recommended for the selected antibiotics to be removed to a considerable degree (up to 95%).
机译:这项研究解决了低压反渗透膜(RE 2521,CSM)工艺可以通过改变操作条件(例如pH = 3、6.5和10)从合成废水中去除某些抗生素(氨苄青霉素和阿莫西林)的可能性;压力= 9、11和13(bar);抗生素浓度= 10、255和500(mg / L),温度= 20、30和40°C。实验是根据Box-benken(使用响应专家方法设计(RSM))使用Design Expert软件进行设计的。通过使用紫外分光光度计(Cecil)在254nm的波长下测量抗生素的浓度。结果显示,阿莫西林和氨苄西林的排斥率分别为73.52%至99.36%和75.1%至98.8%。考虑到溶质截留率和膜的孔隙率表明,被检细菌对膜的主要截留机理是尺寸排阻作用。两种抗生素的渗透通量均为12-18.73 L / m2.h。尽管渗透通量和抗生素排斥分别受操作压力,pH和温度的影响,但操作参数之间的相互作用并没有明显的影响。根据这项研究中获得的结果,建议使用RO膜对所选的抗生素进行较大程度的去除(高达95%)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号