首页> 外文期刊>Journal of Environment and Earth Science >Assessment of Shallow Aquifers Contamination by Failure of on-Site Sewage Disposal System in Ughelli, Western Niger Delta, Nigeria
【24h】

Assessment of Shallow Aquifers Contamination by Failure of on-Site Sewage Disposal System in Ughelli, Western Niger Delta, Nigeria

机译:通过尼日利亚尼日尔三角洲乌格利的现场污水处理系统故障评估浅层含水层污染

获取原文
           

摘要

Hydrochemical quality of shallow groundwater aquifers was investigated to assess the potential of contamination by on-site sewage disposal systems in Ughelli. The results are; pH(5.47 – 7.45 ), Ec (105-483.2μscm), TDS( 58.95-294.7mg/l), Na+(1.8-10.95mg/l ), K+(2.64-9.87mg/l ), Mg2+( 2.40-9.89mg/l), Ca2+(3.01-14.90mg/l) and Fe2+ ( 0.02-0.87mg/l). Others include NO3 (0.04-31.24mg/l), NH3+ (0.015-6.98 mg/l), Cl- (8.5 - 104mg/l), SO4-(2.24-45.75mg/l), PO4-(0.21-2.25mg/l). The quality of most groundwater samples from shallow aquifers falls within the tolerance limits stipulated by the WHO and NSDWQ. However, some groundwater samples revealed the presence of high microbial population including total coliform bacteria count (1.78 – 25MNP/100ml) and Escherichia coli (1.35-9.66 MNP/100ml) above the WHO and NSDWQ standards. Interaction between on-site sewage disposal systems and shallow groundwater aquifers was established by the presence of microbial population, high concentration of NH3+ and slightly elevated concentration of NO3, electrical conductivity and TDS in some the groundwater samples. The extent of contamination of groundwater is strongly influenced by depth of the aquifers, high recharge rate during the wet seasons and availability of permeable soil beneath on-site sewage disposal systems. Consequently the paper recommends that groundwater should be sourced from deeper aquifers and those sourced from shallow aquifer in the area should be disinfected before being used. Key words; Groundwater, aquifer, coliform, contamination, on-site disposal systems, WHO and NSDWQ
机译:调查了浅层地下水含水层的水化学质量,以评估Ughelli现场污水处理系统的潜在污染。结果是; pH(5.47 – 7.45),Ec(105-483.2μscm),TDS(58.95-294.7mg / l),Na +(1.8-10.95mg / l),K +(2.64-9.87mg / l),Mg2 +(2.40-9.89 mg / l),Ca2 +(3.01-14.90mg / l)和Fe2 +(0.02-0.87mg / l)。其他包括NO3(0.04-31.24mg / l),NH3 +(0.015-6.98 mg / l),Cl-(8.5-104mg / l),SO4-(2.24-45.75mg / l),PO4-(0.21-2.25mg / l)。来自浅层含水层的大多数地下水样品的质量均在WHO和NSDWQ规定的容许范围内。但是,一些地下水样本显示存在高微生物种群,包括超过WHO和NSDWQ标准的大肠菌群总数(1.78 – 25MNP / 100ml)和大肠杆菌(1.35-9.66 MNP / 100ml)。某些地下水样品中存在微生物种群,高浓度的NH3 +和较高的NO3浓度,电导率和TDS,从而建立了现场污水处理系统与浅层地下水含水层之间的相互作用。地下水的污染程度受含水层深度,雨季补给率高以及现场污水处理系统下方可渗透土壤的可用性的强烈影响。因此,本文建议应使用该地区较深的含水层中的地下水,而该区域较浅的含水层中的地下水应进行消毒。关键词地下水,含水层,大肠菌群,污染,现场处置系统,世卫组织和NSDWQ

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号