In jar tests, synthetic wastewater was dosed with FeCl3, Fe2(SO4)3, AlCl3or Al2(SO4)3and flocculated. In each case the concentration of the metal ions in the flocculant was 0.043 M. Samples of the mixture were placed under a light microscope that had been fitted with a camera, so that the flocs could be examined. A further experiment was conducted using the same ratio (1:10) of sample to coagulant solutions with gentle mixing on a microscope slide and was also observed under the microscope. Photographs of the samples from both experiments were captured after 1, 30, 60 and 90 min to compare the area covered by the flocs. The area covered by the flocs in the jar test correlates linearly with the area covered by flocs in the microscope slide experiment. An equivalent means of testing can be carried out using microscope observation, which may be preferable to a jar test on the grounds of simplicity and lower cost.
机译:在广口瓶测试中,合成废水中加入了FeCl3,Fe2(SO4)3,AlCl3或Al2(SO4)3并进行了絮凝。在每种情况下,絮凝剂中金属离子的浓度为0.043M。将混合物的样品置于装有照相机的光学显微镜下,以便可以检查絮凝物。使用相同比例(1:10)的样品与凝结剂溶液,并在显微镜载玻片上轻轻混合,进行了进一步的实验,并且还在显微镜下进行了观察。在1、30、60和90分钟后分别拍摄两个实验的样品照片,以比较絮凝物覆盖的面积。广口瓶测试中絮状物覆盖的面积与显微镜载玻片实验中絮状物覆盖的面积线性相关。可以使用显微镜观察进行等效的测试方法,由于简单和成本较低,这可能比广口瓶测试更可取。