With the development of portable X-ray diffractometer for in-situ analysis, powder diffraction patterns are obtained in a diffractometer with a two-dimensional area detector. However, detector system and experimental geometry introduces distortion into acquired data. To obtain accurate diffraction pattern information, it is necessary to apply calibrations. Position of the X-ray incident beam centre on the detector and any non-orthogonality of the detector to the direct beam are the primary considerations. Although many calibration methods have been developed to calculate the intensity-scattering-angle dependence, there are few comparation between them. The purpose of this paper is to investigate these methods. The methods considered include the histogram method, the coordinate transformation method and the Nelder-Mead Simplex method. From the achievement of qualitative analysis angle, we experimentally compare the performance of the methods and illustrate properties such as accuracy and computational efficiency.
机译:随着用于现场分析的便携式X射线衍射仪的发展,在带有二维面积检测器的衍射仪中获得了粉末衍射图。然而,探测器系统和实验几何将失真引入采集的数据中。为了获得准确的衍射图信息,有必要进行校准。 X射线入射光束中心在探测器上的位置以及探测器与直射光束的任何非正交性是主要考虑因素。尽管已经开发了许多校准方法来计算强度散射角的依赖性,但是它们之间的比较很少。本文的目的是研究这些方法。考虑的方法包括直方图方法,坐标变换方法和Nelder-Mead单纯形法。从定性分析的角度出发,我们在实验上比较了这些方法的性能,并说明了诸如准确性和计算效率之类的属性。