首页> 外文期刊>Journal of clinical laboratory analysis. >Comparison of Arkray/ELITech ADAMS HA‐8180V? with Bio‐Rad Variant,TMII Turbo2.0? and Tosoh Bioscience HLC?‐723G8 for HbA1c Determination
【24h】

Comparison of Arkray/ELITech ADAMS HA‐8180V? with Bio‐Rad Variant,TMII Turbo2.0? and Tosoh Bioscience HLC?‐723G8 for HbA1c Determination

机译:Arkray / ELITech ADAMS HA-8180V的比较?使用Bio-Rad Variant,TMII Turbo2.0?和Tosoh Bioscience HLC?-723G8用于HbA1c测定

获取原文
           

摘要

Objective This study aimed to evaluate a new ion-exchange HPLC system to measure hemoglobin A1c (HbA1c) in comparison to two other widely used HPLC systems. Methods Analytical performance and hemoglobin variants detection was assessed on the new Arkray/ELITech ADAMS HA-8180V?, in parallel to Bio-Rad VariantsupTM/supII Turbo2.0? and Tosoh Bioscience HLC?-723G8. A method comparison and concordance for the classification of patients according to the American Diabetes Association (ADA) categories was performed using kappa test. Results ADAMS HA-8180V? demonstrated excellent within-run imprecision (0%) and between-run imprecision: ≤1.21% using blood sample and ≤0.94% using quality controls. Method comparison of ADAMS HA-8180V? with the two other systems yielded very high coefficient correlation ( r 0.995). A very good agreement (kappa value ≥0.81) was observed between methods for the classification of patients according to the ADA categories. In addition, all systems were able to detect the presence of most classical variants such as HbC, HbS, HbD, and HbE. Conclusion The Arkray/ELITech ADAMS HA-8180V? demonstrated high analytical performance similar to previous systems such as BioradsupTM/supVariant II Turbo 2.0? and Tosoh Bioscience HLC?-723G8. The three systems allow a high-quality HbA1c measurement and appeared interchangeable for diabetes diagnosis or for the therapeutic monitoring of patients without hemoglobin variants.
机译:目的本研究旨在评估与其他两种广泛使用的HPLC系统相比,用于测量血红蛋白A1c(HbA1c)的新型离子交换HPLC系统。方法在与Bio-Rad Variant TM II Turbo2.0?平行的新型Arkray / ELITech ADAMS HA-8180V?上评估分析性能和血红蛋白变异检测。和Tosoh Bioscience HLC?-723G8。使用kappa检验对根据美国糖尿病协会(ADA)类别的患者进行分类的方法比较和一致性。结果ADAMS HA-8180V?表现出优异的批内不准确性(0%)和批间不准确性:血液样本≤1.21%,质量控制≤0.94%。 ADAMS HA-8180V的方法比较?其他两个系统的系数相关性非常高(r> 0.995)。在根据ADA类别对患者进行分类的方法之间,观察到非常好的一致性(kappa值≥0.81)。此外,所有系统都能够检测到大多数经典变体,例如HbC,HbS,HbD和HbE。结论Arkray / ELITech ADAMS HA-8180V?表现出与以前的系统(如Biorad TM Variant II Turbo 2.0)类似的高分析性能?和Tosoh Bioscience HLC?-723G8。这三个系统可以进行高质量的HbA1c测量,并且可以互换用于糖尿病诊断或无血红蛋白变异患者的治疗监测。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号