...
首页> 外文期刊>Journal of Chromatography & Separation Techniques >Development of Zwitterionic Hydrophilic Liquid Chromatography (ZIC?¢????HILIC-MS) Metabolomics Method for Shotgun Analysis of Human Urine
【24h】

Development of Zwitterionic Hydrophilic Liquid Chromatography (ZIC?¢????HILIC-MS) Metabolomics Method for Shotgun Analysis of Human Urine

机译:两性离子亲水液相色谱法(ZICTM ¢ HILIC-MS)代谢组学方法用于人类尿液Shot弹枪分析的开发

获取原文
           

摘要

Urine is a product of the body’s metabolism and the majority of the metabolic products exiting via the renal system are rendered polar in order to be water soluble. Resolution of urinary metabolites for metabolomic studies requires the development of HPLC separation techniques that match this feature of biological chemistry. ZIC –HILIC is an ideal candidate to take forward resolution of such metabolites where reverse phase is unable to give adequate separation. Metabolomic data has to be processed by Shotgun multivariate analysis to sift through thousands of analytes and their variables such as ion intensity. In the development of ZIC-HILIC separation with mass spectrometric (IT-ToF) detection, methodological variability have to be minimized so that any Shotgun data analysis does not reveal potential biomarker analytes that are artifacts or are adversely affected of the separation and detection technique. Here, we report the development of a ZIC-HILIC mass spectrometry method that is suitable for SIMCA P+ data analysis of urine. Variables such as resolution, run reproducibility and sample storage temperature were evaluated in tandem with SIMCA P+ data analysis and quality control pre-processing. The developed method couples quality control runs that pre-process and exclude analytes that are insufficiently robust for further candidate biomarker studies. This meant labile analytes that could not be reproduced in 70% of QC runs (which are pools of all samples run that day) were excluded. However, urine samples stored at 4°C for more than 9 months will contain metabolites that will alter and produce small molecule marker artifacts when compared to samples stored at -20°C. In conclusion, the developed method is a robust method of ZIC-HILIC mass spectrometry shotgun analysis suitable for urinary metabolome discovery of robust biomarkers.
机译:尿液是人体新陈代谢的产物,大多数通过肾脏系统排出的代谢产物呈极性,以便水溶性。代谢组学研究中尿液代谢物的解析要求开发与生物化学特征相匹配的HPLC分离技术。 ZIC –HILIC是在逆相无法充分分离的情况下对此类代谢物进行分离的理想选择。代谢组学数据必须通过Shotgun多变量分析进行处理,以筛选成千上万种分析物及其变量(例如离子强度)。在采用质谱(IT-ToF)检测的ZIC-HILIC分离技术的发展中,必须将方法学的可变性降至最低,以便任何Shotgun数据分析都不会显示出可能是伪影或对分离和检测技术造成不利影响的潜在生物标志物分析物。在这里,我们报告了适用于尿液SIMCA P +数据分析的ZIC-HILIC质谱方法的发展。结合SIMCA P +数据分析和质量控制预处理对分辨率,运行再现性和样品存储温度等变量进行了评估。所开发的方法与质量控制运行相结合,可以对预处理进行预处理,并排除对于进一步的候选生物标志物研究而言不够坚固的分析物。这意味着排除了无法在70%的QC运行中复制的不稳定分析物(这是当天运行的所有样品的集合)。但是,与在-20°C储存的样品相比,在4°C储存9个月以上的尿液样品将含有代谢物,这些代谢物会发生变化并产生小分子标记物。总之,开发的方法是ZIC-HILIC质谱shot弹枪分析的一种健壮方法,适用于发现健壮生物标记物的尿代谢组。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号