...
首页> 外文期刊>Journal of Conservative Dentistry >Apical dye leakage of two single-cone root canal core materials (hydrophilic core material and gutta-percha) sealed by different types of endodontic sealers: An in vitro study
【24h】

Apical dye leakage of two single-cone root canal core materials (hydrophilic core material and gutta-percha) sealed by different types of endodontic sealers: An in vitro study

机译:用不同类型的牙髓封闭剂封闭的两种单锥根管核心材料(亲水性核心材料和牙胶)的顶端染料泄漏:一项体外研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Aim of the Study: The aim of this study was to compare the apical sealing ability of two single-cone filling materials when sealed with different types of root canal sealers. Materials and Methods: Eighty extracted maxillary and mandibular canines were selected and their crowns were cut. The root canals were prepared using ProTaper Universal rotary system until size F4 and then divided into seven experimental groups ( n = 10 each) and two control groups ( n = 5 each). Samples of Groups 1, 2, and 3 were filled with single-cone gutta-percha and AH Plus, MTA Fillapex, and EndoSequence BC, respectively. Samples of Groups 4, 5, and 6 were filled similar to the previous groups with the exception of using a single-cone CPoint. Samples of Group 7 were filled with cold gutta-percha lateral condensation technique. To assess apical microleakage, the apical linear dye penetration was measured microscopically and data were statistically analyzed. Results: All experimental groups showed significantly different dye apical leakage values ( P = 0.000). No significant differences were found between Groups 1, 2, 4, 6, and 7 ( P < 0.05). The lowest mean leakage value was observed in Group 6 (0.95 ± 0.56 mm) while Groups 3 (2.68 ± 0.71 mm) and 5 (2.61 ± 0.71 mm) showed significantly higher mean leakage values. Conclusions: The lowest apical leakage value was observed with single-cone CPoint/EndoSequence BC but without significant differences when compared with single-cone gutta-percha/AH Plus, single-cone gutta-percha/MTA Fillapex, single-cone CPoint/AH Plus, and lateral condensation technique. Higher apical leakage values were observed with single-cone gutta-percha/EndoSequence BC and CPoint/MTA Fillapex.
机译:研究的目的:本研究的目的是比较两种单圆锥形填充材料在用不同类型的根管封闭剂封闭时的顶端封闭能力。材料和方法:选择80个拔除的上颌和下颌犬,并切掉其冠。使用ProTaper Universal旋转系统制备根管直至大小为F4,然后将其分为七个实验组(每个n = 10)和两个对照组(每个n = 5)。第1、2和3组的样品分别填充了单锥牙胶和AH Plus,MTA Fillapex和BC EndoSequence。第4、5和6组的样品与以前的组相似,但使用单锥体CPoint除外。第7组样品用冷胶-侧向冷凝技术填充。为了评估根尖的微渗漏,需要在显微镜下测量根尖的线性染料渗透率并进行统计分析。结果:所有实验组均显示出明显不同的染料顶端泄漏值(P = 0.000)。在第1、2、4、6和7组之间没有发现显着差异(P <0.05)。在第6组(0.95±0.56 mm)中观察到最低的平均泄漏值,而在第3组(2.68±0.71 mm)和第5组(2.61±0.71 mm)中观察到明显更高的平均泄漏值。结论:单锥CPoint / EndoSequence BC观察到最低的顶漏值,但与单锥牙胶/ AH Plus,单锥牙胶/ MTA Fillapex,单锥CPoint / AH相比,无显着差异加号和横向冷凝技术。使用单锥牙胶/ EndoSequence BC和CPoint / MTA Fillapex观察到较高的根尖漏泄值。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号