Robust volume-targeted balanced steady-state free-precession coronary magnetic resonance angiography in a breathhold at 3.0 Tesla: a reproducibility study

机译:在3.0特斯拉的屏气中进行稳健的体积目标平衡稳态自由进动冠状动脉磁共振血管造影:再现性研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

BackgroundTransient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique.MethodsA 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner.ResultsThe 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively).ConclusionsThe 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
机译:背景技术瞬态平衡稳态自由进动(bSSFP)已显示出对冠状动脉进行非侵入性评估的巨大希望,但其在3.0 T及更高温度下的利用由于对降低图像质量的视野不均匀性的敏感性而受到阻碍。这项工作的目的是在3.0 T下完善,实施和测试稳健,实用的单呼吸bSSFP冠状动脉MRA序列,并测试该技术的可重复性。方法实现了3D,以体积为目标的高分辨率bSSFP序列。进行基于图像的局部匀场以最小化静态磁场和射频激励场的不均匀性。 15名健康志愿者和3名冠心病患者接受了bSSFP序列检查(扫描时间= 20.5±2.0秒),并在9名受试者中重复了采集。使用半自动化软件工具对图像进行定量分析,并使用回归分析和类内相关系数(ICC)以盲法确定测量的可重复性和可重复性。结果3D bSSFP序列可提供均匀,高质量的图像冠状动脉的描绘(n = 20)。平均可见血管长度为100.5±6.3 mm,锐度为55±2%,与早期报道的导航器选通的bSSFP和梯度回波序列在3.0 T时相吻合。长度测量结果表明,观察者之间的统计学高度高度(r = 0.994 ,ICC = 0.993),观察者内部(r = 0.894,ICC = 0.896)和扫描间一致性(r = 0.980,ICC = 0.974)。此外,ICC值在观察器内,观察者间和扫描间协议中显示出良好的血管直径测量值(分别为ICC = 0.987、0.976和0.961),以及血管清晰度(ICC = 0.989、0.938和0.904),结论使用最新的MR扫描仪进行3D bSSFP采集,该扫描仪配备了最新可用的技术,例如多发射,32通道心线圈以及局部B0和B1 +匀场,可实现加速和可重现的多段在一次屏息中评估3.0 T下的主要冠状动脉。此快速序列对于冠状动脉的功能成像尤其有用,在冠状动脉的功能成像中,采集时间受应激持续时间限制,并且在导航仪门控效率低的情况下,无法在合理的时间段内采集自由呼吸扫描。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号