BackgroundTo overcome flow and electrocardiogram-trigger artifacts in cardiovascular magnetic resonance (CMR), we have implemented a cardiac and respiratory self-gated cine ultra-short echo time (UTE) sequence. We have assessed its performance in healthy mice by comparing the results with those obtained with a self-gated cine fast low angle shot (FLASH) sequence and with echocardiography.Methods2D self-gated cine UTE (TE/TR?=?314?μs/6.2?ms, resolution: 129?×?129?μm, scan time per slice: 5?min 5?sec) and self-gated cine FLASH (TE/TR?=?3?ms/6.2?ms, resolution: 129?×?129?μm, scan time per slice: 4?min 49?sec) images were acquired at 9.4?T. Volume of the left and right ventricular (LV, RV) myocardium as well as the end-diastolic and -systolic volume was segmented manually in MR images and myocardial mass, stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were determined. Statistical differences were analyzed by using Student t test and Bland-Altman analyses.ResultsSelf-gated cine UTE provided high quality images with high contrast-to-noise ratio (CNR) also for the RV myocardium (CNRblood-myocardium?=?25.5?±?7.8). Compared to cine FLASH, susceptibility, motion, and flow artifacts were considerably reduced due to the short TE of 314?μs. The aortic valve was clearly discernible over the entire cardiac cycle. Myocardial mass, SV, EF and CO determined by self-gated UTE were identical to the values measured with self-gated FLASH and showed good agreement to the results obtained by echocardiography.ConclusionsSelf-gated UTE allows for robust measurement of cardiac parameters of diagnostic interest. Image quality is superior to self-gated FLASH, rendering the method a powerful alternative for the assessment of cardiac function at high magnetic fields.
机译:背景技术为了克服心血管磁共振(CMR)中的血流和心电图触发伪影,我们实施了心脏和呼吸自门电影超短回波时间(UTE)序列。我们通过将其与通过自选电影快速低角度拍摄(FLASH)序列和超声心动图获得的结果进行比较来评估其在健康小鼠中的性能.Methods2D自选电影UTE(TE / TR?=?314?μs/ 6.2?ms,分辨率:129?×?129?μm,每片扫描时间:5?min,5?sec)和自选电影快闪(TE / TR?=?3?ms / 6.2?ms,分辨率:129) ××129μm,每片扫描时间:4μmin49μsec)在9.4μT下获得图像。手动在MR图像和心肌质量,每搏量(SV),射血分数(EF)和心输出量(CO)中分割左心室和右心室(LV,RV)的体积以及舒张末期和收缩末期的体积)确定。通过学生t检验和Bland-Altman分析来分析统计差异。 7.8)。与电影FLASH相比,由于314μs的短暂TE,磁化率,运动和流动伪影大大降低。在整个心动周期中主动脉瓣清晰可见。自选门UTE测定的心肌质量,SV,EF和CO与自选门FLASH测得的值相同,并且与超声心动图所获得的结果显示出良好的一致性。结论自选UTE可以可靠地测量具有诊断意义的心脏参数。图像质量优于自选门FLASH,使该方法成为评估强磁场下心功能的有力替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号