Detectability and Usefulness of Automated Whole Breast Ultrasound in Patients with Suspicious Microcalcifications on Mammography: Comparison with Handheld Breast Ultrasound

机译:乳房X光检查可疑微钙化患者自动全乳超声的可检测性和实用性:与手持式乳腺超声的比较

获取原文
           

摘要

Purpose The purpose of this study was to prospectively evaluate the detectability and usefulness of automated whole breast ultrasound (AWUS) and to compare it with handheld breast ultrasound (HHUS) in cases with suspicious microcalcifications identified by mammography. Methods Forty-two patients with 43 suspicious microcalcifications (25 malignant and 18 benign) detected by mammography underwent AWUS, HHUS, and histol-ogic examination. With knowledge of the mammographic findings, HHUS was performed to assess the visibility of the microcalcifications and the presence of associated masses or ductal changes. Two radiologists reviewed the AWUS images in consensus using the same methods employed for HHUS. Detectability of AWUS was compared with that of HHUS and was correlated with histologic and mammographic findings. Results Of the 43 lesions, 32 (74.4%) were detectable by AWUS and 31 (72.1%) by HHUS. No significant differences in sensitivity were found between the two methods ( p =0.998). AWUS detected 96% (24/25) of malignant microcalcifications and 44.4% (8/18) of benign microcalcifications. AWUS was more successful in the detection of malignant vs. benign lesions (96.0% vs. 44.4%, p =0.002), lesions >10 mm vs. ≤10 mm in size (86.7% [26/30] vs. 46.2% [6/13], p =0.009), lesions with a fine pleomorphic or linear shape vs. a round or amorphous or coarse heterogeneous shape (94.7% [18/19] vs. 58.3% [14/24], p =0.021), and lesions associated with a mass or architectural distortion vs. without obvious changes on mammography (100% [19/19] vs. 54.2% [13/24], p =0.022). Conclusion Detectability of AWUS was comparable to that of HHUS in cases where suspicious microcalcifications were identified on mammography. Therefore, AWUS might be helpful in the performance of ultrasound-guided percutaneous procedures for highly suspicious microcalcifications.
机译:目的这项研究的目的是前瞻性评估自动全乳超音波(AWUS)的可检测性和实用性,并将其与手持式乳超B超(HHUS)进行乳房X线照相术确定的可疑微钙化病例进行比较。方法对42例经乳腺X线摄影检查发现可疑微钙化43例(恶性25例,良性18例)的患者进行AWUS,HHUS和组织学检查。在了解了乳腺X线照片的基础上,进行了HHUS以评估微钙化的可见性以及相关肿块或导管改变的存在。两名放射科医生使用与HHUS相同的方法一致地检查了AWUS图像。将AWUS的可检测性与HHUS的可检测性进行了比较,并将其与组织学和乳房X线照片相关。结果在43个病变中,AWUS可检测到32个(74.4%),HHUS可检测到31个(72.1%)。两种方法之间在灵敏度上没有显着差异(p = 0.998)。 AWUS检测到96%(24/25)的恶性微钙化和44.4%(8/18)的良性微钙化。 AWUS在检出恶性与良性病变方面更为成功(96.0%对44.4%,p = 0.002),病变大小大于10mm对小于等于10mm(86.7%[26/30]对46.2%[ [6/13],p = 0.009),具有细多形或线性形状与圆形或无定形或粗糙异质形状的病变(94.7%[18/19]与58.3%[14/24],p = 0.021) ,以及与肿块或建筑畸变相关的病变,而钼靶检查无明显变化(100%[19/19]比54.2%[13/24],p = 0.022)。结论在乳腺X线照相术中发现可疑微钙化的情况下,AWUS的可检测性可与HHUS相比。因此,对于高度可疑的微钙化,AWUS可能有助于超声引导的经皮手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号