摘要

Dose verifications for intensity-modulated radiation therapy (IMRT) are generally performed once before treatment. A 39-fraction treatment course for prostate cancer delivers a dose prescription of 78 Gy in eight weeks. Any changes in multileaf collimator leaf position over the treatment course may affect the dosimetry. To evaluate the magnitude of deviations from the predicted dose over an entire treatment course with MLC leaf calibrations performed every two weeks, we tracked weekly changes in relative dose error distributions measured with two-dimensional (2D) beam-by-beam analysis. We compared the dosimetric results from 20 consecutive patient-specific IMRT quality assurance (QA) tests using beam-by-beam analysis and a 2D diode detector array to the dose plans calculated by the treatment planning system (TPS). We added back the resulting relative dose error measured weekly into the original dose grid for each beam. To validate the prediction method, the predicted doses and dose distributions were compared to the measurements using an ionization chamber and film. The predicted doses were in good agreement, within 2% of the measured doses, and the predicted dose distributions also presented good agreement with the measured distributions. Dose verification results measured once as a pretreatment QA test were not completely stable, as results of weekly beam-by-beam analysis showed some variation. Because dosimetric errors throughout the treatment course were averaged, the overall dosimetric impact to patients was small.PACS numbers: 87.55.D-, 87.55.dk, 87.55.km, 87.55.Qr
机译:强度调制放射治疗(IMRT)的剂量验证通常在治疗前进行一次。前列腺癌的39个疗程可在8周内提供78 Gy的剂量处方。在整个治疗过程中,多叶准直器叶片位置的任何变化都可能影响剂量测定。为了评估每两周进行的MLC叶片校准在整个治疗过程中与预期剂量的偏差幅度,我们跟踪了通过二维(2D)逐束分析测量的相对剂量误差分布的每周变化。我们将连续20项特定于患者的IMRT质量保证(QA)测试(使用逐束分析和2D二极管检测器阵列)与由治疗计划系统(TPS)计算出的剂量计划进行了剂量学比较。我们将每周测量的结果相对剂量误差加回到每个光束的原始剂量网格中。为了验证预测方法,将预测的剂量和剂量分布与使用电离室和薄膜的测量值进行比较。预测剂量非常吻合,在测得剂量的2%之内,并且预测剂量分布也与测得分布非常吻合。一次作为预处理QA测试测得的剂量验证结果并不完全稳定,因为每周逐束分析的结果显示出一些差异。由于整个治疗过程中的剂量误差均是平均的,因此对患者的总体剂量影响很小.PACS编号:87.55.D-,87.55.dk,87.55.km,87.55.Qr

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号