Oil dampers installed on the first floor of an eight-story steel building were completely destroyed during the 2011 Great East Japan Earthquake. It is believed to be the first time in the world that real oil dampers in service failed due to earthquakes. Before this failure event, the actual performance of buildings that use oil dampers during catastrophic earthquakes has never been verified. Investigating the cause of the damage of the oil dampers is thus necessary and urgent. In this paper, a comprehensive identification was conducted to rebuild the numerical model of this damped structure equipped with/without damaged oil dampers using the measurement data of the installed monitoring system. Furthermore, the damage process of the oil dampers was postulated based on the identification and simulation results. The limit states of the oil dampers were studied. Based on the damages of the dampers and connection, the oil dampers experienced the displacement limit state when the allowable displacement limit was surpassed and the central cylinder pushed against the abutment. The insufficient stroke limit is the main cause of the collision between the damper and the abutment on the floor, which finally led to the failure of the oil dampers.
机译:在2011年东日本大地震中,安装在八层钢结构建筑一楼的减震器被完全摧毁。据信,这是世界上第一次真正的减震器在地震中失效。在此故障事件发生之前,在灾难性地震中使用减震器的建筑物的实际性能尚未得到验证。因此,调查油阀的损坏原因是必要和紧迫的。在本文中,通过使用已安装的监控系统的测量数据,进行了全面的识别,以重建配备/不损坏油阻尼器的这种阻尼结构的数值模型。此外,基于辨识和仿真结果,推测了油阀的损坏过程。研究了油阀的极限状态。基于减震器和连接件的损坏,当超过允许的排量极限并且中心油缸被推向基台时,油压减震器处于排量极限状态。行程极限不足是阻尼器和地板上的支座之间发生碰撞的主要原因,最终导致了阻尼器的故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号