首页> 外文期刊>Journal of Applied Research and Technology >Experimental Assessment of Derating Guidelines Applied to Power Electronics Converters
【24h】

Experimental Assessment of Derating Guidelines Applied to Power Electronics Converters

机译:电力电子转换器降额指南的实验评估

获取原文
           

摘要

Power transistors are the most vulnerable components in switching converters, and derating is usually applied to increase their reliability. In this paper, the effectiveness of derating guidelines is experimentally assessed using a push-pull DC-DC converter as a case study, operating in three different environments. After measuring the electrical variables and temperature, reliability was predicted following the guidelines in MIL HDBK 217F. The sensitivity analysis performed indicates that temperature has the largest impact on reliability, followed by environment and device quality. The results obtained demonstrate that a derating procedure based solely on DC ratings does not ensure an adequate performance. Therefore, additional guidelines are suggested to help increase the overall reliability obtained from a power circuit.
机译:功率晶体管是开关转换器中最易损坏的组件,通常通过降低额定功率来提高其可靠性。在本文中,使用推挽式DC-DC转换器作为案例研究,在三种不同的环境中运行,通过实验评估了降额指南的有效性。在测量了电气变量和温度之后,按照MIL HDBK 217F中的准则预测了可靠性。进行的灵敏度分析表明,温度对可靠性的影响最大,其次是环境和设备质量。获得的结果表明,仅基于直流额定值的降额程序不能确保足够的性能。因此,建议使用其他准则来帮助提高从电源电路获得的整体可靠性。