首页> 外文期刊>Journal of applied clinical medical physics / >A novel approach for superficial intraoperative radiotherapy (IORT) using a 50 kV X‐ray source: a technical and case report
【24h】

A novel approach for superficial intraoperative radiotherapy (IORT) using a 50 kV X‐ray source: a technical and case report

机译:一种使用50 kV X射线源进行浅表术中放射治疗(IORT)的新方法:技术和病例报告

获取原文
           

摘要

The use of IORT as a treatment modality for patients with close or positive margins has increased over the past decade. For situations where a flat area (up to 6 cm in diameter) has to be treated intraoperatively, new applicators for superficial treatment with a miniature X-ray source (INTRABEAM system) were developed. Here we report our evaluation of the dosimetric characteristics of these new applicators and their first clinical use. Each of these flat and surface applicators consists of a radiation protective metal tube and a flattening filter, which converts the spherical dose distribution of the X-ray source into a flat one. The homogeneity of each dose distribution and depth-dose measurements were evaluated using film dosimetry in a solid water phantom and a soft X-ray ionization chamber in a water tank. The first patient was treated with 5 Gy delivered in 5 mm using a 4 cm FLAT applicator over 21 minutes. The flat applicators show the maximum homogeneity, with a uniformity ratio of 1.02-1.08 in certain depths. In 1 mm depth surface applicators show a uniformity ratio of 1.15-1.28. They also show a higher dose rate and a steeper dose gradient compared to the flat applicators. The results of this investigation demonstrated that the flat and surface applicators have unique dosimetric characteristics that need to be considered during the treatment planning stages. This work also showed that it is possible to perform a superficial localized IORT which provides new application possibilities for use of the INTRABEAM system.PACS number: 87.55.ne
机译:在过去十年中,使用IORT作为具有接近或正向切缘的患者的治疗方式已经有所增加。对于必须在手术中处理扁平区域(直径最大6厘米)的情况,开发了新的涂药器,用于使用微型X射线源(INTRABEAM系统)进行表面治疗。在这里,我们报告了对这些新型喷头的剂量特性及其首次临床应用的评估。这些平面和表面施加器均由防辐射金属管和压平滤光片组成,该滤光片将X射线源的球形剂量分布转换为扁平剂量。使用薄膜剂量测定法在固态水体模中和水箱中的软X射线电离室中使用薄膜剂量测定法评估每种剂量分布和深度剂量测量的均匀性。使用4 cm FLAT涂抹器在5分钟内以5 mm递送5 Gy来治疗首例患者,时间为21分钟。扁平涂药器显示出最大的均匀性,在某些深度均匀度为1.02-1.08。在1毫米深处,表面涂抹器的均匀度为1.15-1.28。与平板式施药器相比,它们还显示出更高的剂量率和更陡峭的剂量梯度。这项研究的结果表明,平面涂药器和表面涂药器具有独特的剂量特性,在治疗计划阶段需要考虑这些特性。这项工作还表明可以执行表面局部的IORT,这为使用INTRABEAM系统提供了新的应用可能性。PACS编号:87.55.ne

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号