This paper describes the applicability of a Hg-electroplated-Pt ultramicroelectrode in the quantification of elemental sulphur in naphtha samples by square-wave voltammetry. A reproducible deposition methodology was studied and is reported in this paper. This methodology is innovative and relies on the quality of the mercury stock solution to obtain reproducible surfaces required for the analytical methodology. All analyses were performed using a Hg-electroplated-Pt ultramicroelectrode (Hg-Pt UME) due to the low sensibility of such devices to ohmic drops in resistive solutions. The responses of the peak areas in voltammetric experiments were linear in all of the range studied. The method developed here is accurate and reproducible, with a detection limit of 0.010 mg L−1and a good recovery range for both standard solutions of elemental sulphur (85 to 99%) and real naphtha sample (79%). These results attest to the potential for the application of this electroanalytical methodology in determining elemental sulphur in naphtha samples containing mercaptans and disulphides.
机译:本文介绍了汞-电镀-铂超微电极在方波伏安法定量石脑油样品中元素硫中的适用性。研究了可重现的沉积方法,并在本文中进行了报道。该方法是创新性的,并依赖于汞储备溶液的质量来获得分析方法所需的可重现表面。由于此类设备对电阻性溶液中的欧姆滴的敏感性较低,因此使用Hg-Pt电镀超微电极(Hg-Pt UME)进行所有分析。伏安法实验中峰面积的响应在所有研究范围内都是线性的。此处开发的方法准确且可重复,检出限为0.010 µg L-1,对于元素硫的标准溶液(85%至99%)和石脑油样品(79%)均具有良好的回收率。这些结果证明了这种电分析方法在测定含硫醇和二硫化物的石脑油样品中的元素硫中的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号