Existing Dutch guidelines for the design of the drinking water and hot water system of non-residential buildings are based on outdated assumptions on peak water demand or on unfounded assumptions on hot water demand. They generally overestimate peak demand values required for the design of an efficient and reliable water system. Recently, a procedure was developed based on the end-use model SIMDEUM to derive design-demand-equations for peak demand values of both cold and hot water during various time steps for several types and sizes of non-residential buildings, viz. offices, hotels and nursing homes. In this paper, the design-demand-equations are validated with measurements of cold and hot water patterns on a per second base and with surveys. The good correlation between the simulated water demand patterns and the measured patterns indicates that the basis of the design-demand-equations, the SIMDEUM simulated standardised buildings, is solid. Surveys were held to investigate whether the construction of the standardised buildings based on the dominant variable corresponds with practice. Surveys show that it is difficult to find relationships to equip the standardised buildings with users and appliances. However, the validation proves that with a proper estimation of the number of users and appliances in only the dominant functional room of the standardised buildings, SIMDEUM renders a realistic cold and hot water diurnal demand pattern. Furthermore, the new design-demand-equations based on these standardised buildings give a better prediction of the measured peak values for cold water flow than the existing guidelines. Moreover, the new design-demand-equations can predict hot water use well. In this paper it is illustrated that the new design-demand-equations lead to reliable and improved designs of building installations and water heater capacity, resulting in more hygienic and economical installations.
机译:荷兰现行的非住宅建筑饮用水和热水系统设计指南基于对高峰用水需求的过时假设或对热水需求的无根据的假设。他们通常高估了设计高效,可靠的供水系统所需的峰值需求值。最近,基于最终用途模型SIMDEUM开发了一种程序,以得出针对几种类型和大小的非住宅建筑在不同时间段内的冷热水需求峰值的设计需求方程。办公室,旅馆和疗养院。在本文中,设计需求方程式通过每秒一次的冷热水模式测量和调查进行验证。模拟的需水模式与实测模式之间的良好相关性表明,设计需求方程式(SIMDEUM模拟标准化建筑物)的基础是坚实的。进行了调查以调查基于主导变量的标准化建筑物的建造是否与实践相符。调查显示,很难找到关系为标准化建筑物配备用户和设备。但是,验证证明,仅对标准化建筑物中占主导地位的功能室中的用户和设备数量进行适当估计,SIMDEUM便可以得出逼真的冷,热水日需求模式。此外,基于这些标准化建筑物的新设计需求公式比现有准则更好地预测了冷水流量的测量峰值。而且,新的设计需求方程式可以很好地预测热水使用量。本文说明,新的设计需求方程式导致可靠且改进的建筑安装和热水器容量设计,从而使安装更加卫生和经济。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号