Comparison of tissue oxygenation achieved breathing oxygen from a demand valve with four different mask configurations

机译:比较具有四种不同面罩配置的从需求阀呼吸氧气的组织充氧

获取原文
           

摘要

Introduction High concentration normobaric oxygen (Osub2/sub) is a priority in treating divers with suspected decompression illness. The effect of different Osub2/sub mask configurations on tissue oxygenation when breathing with a demand valve was evaluated. Methods Sixteen divers had tissue oxygen partial pressure (Psubtc/subOsub2/sub) measured at six limb sites. Participants breathed Osub2/sub from a demand valve using: an intraoral mask (IOM?) with and without a nose clip (NC), a pocket face mask and an oronasal mask. In-line inspired Osub2/sub (FsubI/subOsub2/sub) and nasopharyngeal FsubI/subOsub2/sub were measured. Participants provided subjective ratings of mask comfort, ease of breathing and holding in position. Results Psubtc/subOsub2/sub values and nasopharyngeal FsubI/subOsub2/sub (median and range) were greatest using the IOM? with NC and similar with the IOM? without NC. Osub2/sub measurements were lowest with the oronasal mask which also was rated as the most difficult to breathe from and to hold in position. The pocket face mask was reported as the most comfortable to wear. The NC was widely described as uncomfortable. The IOM? and pocket face mask were rated best for ease of breathing. The IOM? was rated as the easiest to hold in position. Conclusion Of the commonly available Osub2/sub masks for use with a demand valve, the IOM? with NC achieved the highest Psubtc/subOsub2/sub values. Psubtc/subOsub2/sub and nasopharyngeal FsubI/subOsub2/sub values were similar between the IOM? with and without NC. Given the reported discomfort of the NC, the IOM? without NC may be the best option.
机译:简介高浓度常压氧气(O 2 )是治疗潜水员怀疑患有减压病的优先事项。评估了不同的O 2 口罩构型对按需呼吸时组织氧合的影响。方法对十六名潜水员在六个肢体部位测量组织氧分压(P tc O 2 )。参与者使用以下设备从需气阀中呼吸O 2 :带和不带鼻夹(NC)的口内口罩(IOM?),袖珍口罩和口鼻罩。在线启发式O 2 (F I O 2 )和鼻咽F I O 2 < / sub>。参与者对口罩的舒适度,呼吸舒适度和保持姿势的主观评分。结果使用IOM,P tc O 2 值和鼻咽F I O 2 (中值和范围)最大?与NC和与IOM类似?没有NC。口鼻罩的O 2 测量值最低,也被认为是最难呼吸和保持就位的口罩。据报道,口袋口罩最舒适。 NC被广泛描述为不舒服。 IOM?和袖口口罩被评为呼吸最佳。 IOM?被评为最容易就位的人。结论在通常用于需求阀的O 2 口罩中,IOM是什么? NC的P tc O 2 值最高。 IOM之间P tc O 2 和鼻咽F I O 2 值相似吗?有无NC。考虑到NC的不适感,IOM?没有NC可能是最好的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号