首页> 外文期刊>Der Pharmacia Lettre >Chromatographic Method Development for Rapid Simultaneous Estimation of Calcium Pantothenate and Biotin in Pure and Tablet Dosage Form
【24h】

Chromatographic Method Development for Rapid Simultaneous Estimation of Calcium Pantothenate and Biotin in Pure and Tablet Dosage Form

机译:快速同时估算纯净剂量和片剂剂量形式的泛酸钙和生物素的色谱方法开发

获取原文
           

摘要

A simple, precise and reliable RP-HPLC (Reverse phase high-performance liquid chromatography method) was developed and validated for the simultaneous estimation of calcium pantothenate (CP) and biotin (BI) in pure and their tablet dosage form. The chromatographic separation is being achieved by using Cosmosil C18 column (250 mm × 4.6 mm i.d, 5 μm) and mobile phase consisting of buffer (Mono basic potassium dihydrogen orthophosphate with 10% orthophosphoric acid, pH adjusted to 2.20 ± 0.05) and methanol (70:30 % v/v) with the flow rate of 1.0 ml/min. The PDA detector was used as detector, measuring the response at 210 nm. The retention time was found to be 4.5 and 9.8 min for CP and BI respectively. The linearity of the drugs was acquired in the range of 50-150 μg/ml and 5-15 μg/ml for CP and BI respectively. ICH guidelines were used for the validation of the results obtained.
机译:开发了一种简单,精确和可靠的RP-HPLC(反相高效液相色谱方法),并进行了验证,该方法可同时估算纯及其片剂剂型中的泛酸钙(CP)和生物素(BI)。色谱分离是通过使用Cosmosil C18色谱柱(250 mm×4.6 mm内径,5μm)和流动相实现的,流动相由缓冲液(正碱性单磷酸二氢钾正磷酸盐和10%正磷酸,pH值调节至2.20±0.05)和甲醇( 70:30%v / v),流速为1.0 ml / min。 PDA检测器用作检测器,测量210 nm处的响应。发现CP和BI的保留时间分别为4.5和9.8分钟。对于CP和BI,药物的线性分别在50-150μg/ ml和5-15μg/ ml的范围内。 ICH指南用于验证所获得的结果。