首页> 外文期刊>Dental Press Journal of Orthodontics >Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires
【24h】

Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires

机译:正畸弓丝自锁扎带与传统托槽之间的摩擦阻力比较

获取原文
       

摘要

OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. RESULTS: Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P 0.05), which also differed from each other (P 0.05). As for the type of wire, 0.019 x 0.025-in steel wire (5.67 ± 3.97) showed lower means (P 0.05) than 0.16-in NiTi wire (8.26 ± 10.92) and 0.016 x 0.021-in NiTi wire (8.51 ± 7.95), which did not differ from each other (P 0.05). No statistical differences (P 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. CONCLUSIONS: Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied
机译:目的:比较自绑扎带和绑在不同类型导线上的传统支架之间的摩擦阻力。材料与方法:使用Abzil Kirium Capelozza(模式I)和Easy Clip(Roth处方)门牙支架。使用弹性绑扎线或0.10英寸绑扎线将扎线绑到Abzil支架上。评估了三种类型的正畸弓丝合金:0.016英寸NiTi丝,0.016 x 0.021英寸NiTi丝和0.019 x 0.025英寸钢丝。对每个支架-弓丝角度组合进行十次观察。将支架安装在特殊的设备中,该设备相对于电线成90度放置,并以两个角度进行测试。在通用试验机中以5mm / min和10mm的位移进行摩擦试验。将平均值(MPa)提交给ANOVA和Tukey检验,检验的显着性为5%。在SEM下观察电线和支架的表面。结果:钢制托槽(16.48±8.31)的摩擦阻力均值高于弹性托槽(4.29±2.16)和自结扎托槽(1.66±1.57)(P <0.05),两者之间也存在差异( P <0.05)。至于导线类型,0.019 x 0.025英寸钢丝(5.67±3.97)的平均值(P <0.05)低于0.16英寸NiTi导线(8.26±10.92)和0.016 x 0.021英寸NiTi导线(8.51±7.95) ),彼此之间没有差异(P> 0.05)。在零(7.76±8.46)和五度(7.19±7.93)角度之间未发现统计学差异(P> 0.05)。结论:摩擦不仅受支架类型的影响,还受结扎系统的影响。对于所研究的支架和线材,观察到了不同的形态学方面

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号